Evidence map›Paper›PMID 36483065›Full record

ArticleAdvances in radiation oncology

Effect of Body Mass Factors on Setup Displacement in Gynecologic Tumors and Subsequent Effect on PTV Margins.

Zaheeda Mulla, Rania Hashem, Abdullah AlMohamad, Amina Weber, Hanadi Habibullah, Ghassan Abdulmoula, Mohamed G Mohiuddin, Reem Ujaimi

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Advances in radiation oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07676032 (The Impact of Body Composition on Setup Errors in Patients Undergoing Radiotherapy With Thermoplastic Mask Immobilization), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07676032 not yet recruitingnot on this map

The Impact of Body Composition on Setup Errors in Patients Undergoing Radiotherapy With Thermoplastic Mask Immobilization: A Single-Center Prospective Cohort Study

Typeobservational_patient_registrySponsorShijiazhuang People's HospitalRan2026 to 2027Enrolled150ConditionsMalignant Neoplasms
3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Zaheeda MullaDepartment of Oncology, King Faisal Specialist Hospital and Research Center-Jeddah, Jeddah, Saudi Arabia.
Rania HashemDepartment of Radiology, King Abdul-Aziz University Hospital, Jeddah, Saudi Arabia.
Abdullah AlMohamadDepartment of Oncology, King Faisal Specialist Hospital and Research Center-Jeddah, Jeddah, Saudi Arabia.
Amina WeberDepartment of Oncology, King Faisal Specialist Hospital and Research Center-Jeddah, Jeddah, Saudi Arabia.
Hanadi HabibullahDepartment of Oncology, King Faisal Specialist Hospital and Research Center-Jeddah, Jeddah, Saudi Arabia.
Ghassan AbdulmoulaDepartment of Oncology, King Faisal Specialist Hospital and Research Center-Jeddah, Jeddah, Saudi Arabia.
Mohamed G MohiuddinDepartment of Radiology, King Abdul-Aziz University Hospital, Jeddah, Saudi Arabia.
Reem UjaimiDepartment of Radiology, Faculty of Medicine, King Abdul-Aziz University, Jeddah, Saudi Arabia.
King Faisal Specialist Hospital & Research Centre · SAKing Abdul Aziz University Hospital · SA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study aimed to analyze the effect of body mass factors (BMFs) on setup errors in gynecologic tumors, and whether the planned tumor volumes (PTVs) are adequate for obese patients. Methods: This was a retrospective study of 46 consecutive female patients with gynecologic tumors who were treated with volumetric modulated arc therapy. Setup accuracy was verified using daily cone beam computed tomography. Accuracy was determined for each fraction by testing 2 different PTVs (cutoff I = ≤0.7 cm; cutoff II = ≤1.0 cm). A pooled analysis was conducted to test the association between accuracy levels (within vs beyond PTV) and the mean and variance of body mass index (BMI), umbilical (UC), and hip circumference (HC). A receiver operating characteristics curve analysis was carried out to test the sensitivity of BMI, UC, and HC in predicting inaccurate setup. Results: A significant association between BMFs and level of accuracy was observed in the lateral and vertical directions, but not in the longitudinal direction. In the lateral direction, inaccurate setups were associated with a greater BMI (mean difference: ∼3.50 kg/m Conclusions: The accuracy of radiation therapy setups for gynecologic tumors is highly sensitive to patients' BMI, notably in the lateral and vertical directions. We suggest that daily cone beam computed tomography should be applied on patients with a BMI >30.3 kg/m

Identifiers

PMID36483065
PMCPMC9723305
OpenAlexW4307400960

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.