Evidence map›Paper›PMID 36482095›Full record

ArticleCardiovascular and interventional radiology2023

Construction and Validation of a Benchtop Model for Testing of Mechanical Thrombectomy Devices for Pulmonary Embolism.

Sarosh Irfan Madhani, Jorge Arturo Larco, Yang Liu, Mehdi Abbasi, Adnan Hussain Shahid, Omar Yasin, Victoria Sears, Jonathan Morris, Mike Rosenthal, Scott Baron and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Cardiovascular and interventional radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 68% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 4 institutions in 2 countries.

Sarosh Irfan Madhani *Department of Neurosurgery, University of California, San Francisco, CA, USA.ORCID http://orcid.org/0000-0003-4855-8487
Jorge Arturo Larco *Department of Radiology, Mayo Clinic, Rochester, MN, USA.
Yang LiuGlobal Institute of Future Technologies, Shanghai Jiao Tong University, Shanghai, China.
Mehdi AbbasiDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Adnan Hussain ShahidDepartment of Neurosurgery, Mayo Clinic, Rochester, MN, USA.
Omar YasinDepartment of Cardiology, Mayo Clinic, Rochester, MN, USA.
Victoria SearsDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Jonathan MorrisDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Mike RosenthalEndovascular Engineering, Menlo Park, CA, USA.
Scott BaronEndovascular Engineering, Menlo Park, CA, USA.
Luis SavastanoDepartment of Neurosurgery, University of California, San Francisco, CA, USA. luis.savastano@ucsf.edu.
Mayo Clinic · USMenlo School · USUniversity of California, San Francisco · USShanghai Jiao Tong University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aims to define the process of designing and manufacturing 3D printed and glass models of the pulmonary artery (PA) and utilizing them in a test bed for evaluation of devices for mechanical thrombectomy of pulmonary embolism (PE). MATERIALS AND

methodsPatient derived computed tomography angiography (CTA) images of the PA were digitally converted into a hollowed-out structure and translated into clear 3D printed and glass models. A test bed was created using a peristaltic pump and silicone tubing connected to the models. Human clot analogs were then prepared and injected within the models. Thrombectomy testing was done using clinically used predicates and baseline characteristics of the models were evaluated by independent interventionalists.

resultsThe mean sizes of the main pulmonary artery (MPA) for the 3D printed model and glass model were 30.4 mm and 29.2 mm, mimicking those of the patient's PA obtained on CTA. Heterogeneous human clot analogs were created with fibrin composition ranging from 60 to 30%. Mechanical thrombectomy was successfully attempted by independent interventionalists. Both the 3D printed, and glass model were appraised as very good for multiple attributes.

conclusionA complete test bed using 3D printed and glass models of the PA with human clot analogs was created for testing of mechanical thrombectomy devices for PE.

Indexed as

Pulmonary EmbolismThrombosisAngiographyComputed Tomography AngiographyHumansPulmonary ArteryThrombectomy

Identifiers

PMID36482095
OpenAlexW4310952197

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.