ArticleCardiovascular and interventional radiology2023
Construction and Validation of a Benchtop Model for Testing of Mechanical Thrombectomy Devices for Pulmonary Embolism.
Article in Cardiovascular and interventional radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis study aims to define the process of designing and manufacturing 3D printed and glass models of the pulmonary artery (PA) and utilizing them in a test bed for evaluation of devices for mechanical thrombectomy of pulmonary embolism (PE). MATERIALS AND
methodsPatient derived computed tomography angiography (CTA) images of the PA were digitally converted into a hollowed-out structure and translated into clear 3D printed and glass models. A test bed was created using a peristaltic pump and silicone tubing connected to the models. Human clot analogs were then prepared and injected within the models. Thrombectomy testing was done using clinically used predicates and baseline characteristics of the models were evaluated by independent interventionalists.
resultsThe mean sizes of the main pulmonary artery (MPA) for the 3D printed model and glass model were 30.4 mm and 29.2 mm, mimicking those of the patient's PA obtained on CTA. Heterogeneous human clot analogs were created with fibrin composition ranging from 60 to 30%. Mechanical thrombectomy was successfully attempted by independent interventionalists. Both the 3D printed, and glass model were appraised as very good for multiple attributes.
conclusionA complete test bed using 3D printed and glass models of the PA with human clot analogs was created for testing of mechanical thrombectomy devices for PE.