Evidence map›Paper›PMID 36480146›Full record

ArticleNetherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation2023

Short-term outcome after transcatheter aortic valve replacement with a novel balloon-expandable valve.

J Halim, P den Heijer, B van den Branden, M Meuwissen, J Vos, B Schölzel, A IJsselmuiden

Open access · diamondAbstract read
In one paragraph

Article in Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Observational
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

J HalimDepartment of Cardiology, Amphia Hospital Breda, Breda, The Netherlands. jhalim@amphia.nl.
P den HeijerDepartment of Cardiology, Amphia Hospital Breda, Breda, The Netherlands.
B van den BrandenDepartment of Cardiology, Amphia Hospital Breda, Breda, The Netherlands.
M MeuwissenDepartment of Cardiology, Amphia Hospital Breda, Breda, The Netherlands.
J VosDepartment of Cardiology, Amphia Hospital Breda, Breda, The Netherlands.
B SchölzelDepartment of Cardiology, Amphia Hospital Breda, Breda, The Netherlands.
A IJsselmuidenDepartment of Cardiology, Amphia Hospital Breda, Breda, The Netherlands.
Amphia Ziekenhuis · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTranscatheter aortic valve replacement (TAVR) has been expanding rapidly with numerous transcatheter heart valve (THV) systems currently available. The Myval balloon-expandable (BE) valve (Meril Life Sciences Pvt. Ltd., India) is a novel THV system indicated for the treatment of patients with severe aortic stenosis. The primary objective of this study is to assess the safety and performance of the Myval BE valve.

methodsIn this prospective single-centre study, 120 consecutive patients who underwent TAVR with the Myval BE valve were included. Clinical outcomes were evaluated at 30 days and 6 months using Valve Academic Research Consortium‑2 criteria. All-cause mortality, stroke, acute kidney injury, major vascular complications, moderate or severe paravalvular leakage (PVL) and need for a permanent pacemaker implantation (PPI) were investigated.

resultsAt 6‑month follow-up, all-cause death and cardiac death were seen in 5.8% and 0.8% of the patients respectively. Periprocedural stroke and need for PPI were both seen in 3.3% of the patients. Access-site-related vascular and bleeding complications were absent. Improved valve haemodynamics and no moderate to severe PVL could be seen at 30 days. An intermediate valve size was selected in 51% of the patients.

conclusionsThe Myval BE valve demonstrates improved valve haemodynamics, absence of moderate to severe PVL and good safety outcomes at 6‑month follow-up with low cardiac death rate and acceptable rates of permanent pacemaker implantation and periprocedural stroke. Future randomised controlled trials will further establish the clinical utility of the Myval BE valve.

Indexed as

Aortic stenosisBalloon-expandable valveTranscatheter aortic valve replacement

Identifiers

PMID36480146
PMCPMC10667167
OpenAlexW4310956860

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked