Evidence map›Paper›PMID 36479590›Full record

ArticleMethodsX2022

Effect of time and storage temperature on canine and feline erythrocyte sedimentation rate.

Eleonora Gori, Anna Pasquini, Daniela Diamanti, Carlo Carletti, Veronica Marchetti

Open access · goldAbstract read
In one paragraph

Article in MethodsX, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Erythrocyte Sedimentation Rate as a Monitoring Marker in the Canine Intensive Care Unit.Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Eleonora GoriDepartment of Veterinary Sciences, University of Pisa, University of Pisa, Via Livornese snc, 56121, Pisa (PI), Italy.
Anna PasquiniDepartment of Veterinary Sciences, University of Pisa, University of Pisa, Via Livornese snc, 56121, Pisa (PI), Italy.
Daniela DiamantiDIESSE Diagnostica Senese Spa, Via Strada dei Laghi 35-39, Z.I., Casone, Ingresso 6 Monteriggioni, 53035, Siena (SI), Italy.
Carlo CarlettiDIESSE Diagnostica Senese Spa, Via Strada dei Laghi 35-39, Z.I., Casone, Ingresso 6 Monteriggioni, 53035, Siena (SI), Italy.
Veronica MarchettiDepartment of Veterinary Sciences, University of Pisa, University of Pisa, Via Livornese snc, 56121, Pisa (PI), Italy.
University of Pisa · ITAzienda Ospedaliera Universitaria Senese · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We aimed to test the influence of storage temperature and time for canine and feline ESR. Forty dogs and 12 cats were included and randomly allocated in "room temperature" and "refrigerated" groups. Both groups had the T0 ESR measures few minutes after complete blood count. Afterwards, room temperature group had ESR measured at 2, 4, 6 and 8h after T0, whereas the "refrigerated" group had the blood sample stored at 4-6°C for 24 and then T24h ESR was measured. In each ESR measurement, [1] blood samples were put on a tube rocker waiting for ESR analysis; [2] before inserting the blood tube in the MINI-PET ESR instrument, samples were gently mixed again by complete inversion 10 times; (3) each mixed blood tube was inserted in the one of the four MINI-PET tubes position; (4) on the machine display, patient's species has to be chosen and the 14 minutes countdown started; (5) after the 14 minutes optical reading, the ESR result (mm/h) is displayed on the machine. ESR of canine samples at room temperature were significantly stable until T6, while feline samples remained stable at T8. After 24h at refrigerated temperature, both canine and feline samples were stable. • MINI-PET is an ESR automatic continuous-loading instrument that can analyze up to four EDTA blood samples simultaneously using an optical system that measures the erythrocytes sedimentation level • We aimed to test influence of storage temperature and time for canine and feline ESR • At room temperature, dogs' samples were stable within 6 hours from collection, and cats' samples were stable until 8h. At refrigerated temperature, there was no difference in T0-T24 ESR in both canine and feline samples.

Indexed as

CatDogEDTARed blood cellsSedimentationStability

Identifiers

PMID36479590
PMCPMC9720102
OpenAlexW4309927675

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.