The effect of the design of the orthosis on the axial load transmission of two flexion abduction orthoses used in treating congenital hip dysplasia.

Paul Schwanitz von Keitz, Dana Kleimeier, Christoph Fabian Lutter, Mirko Rehberg, Wolfram Mittelmeier, Richard Kasch, Katrin Osmanski-Zenk, Susanne Fröhlich

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Paul Schwanitz von KeitzRehafachzentrum Bad Füssing, Orthopädische Klinik, Waldstraße 12, 94072, Bad Füssing, Germany.
Dana KleimeierInstitut für Bioinformatik, Universitätsmedizin Greifswald, Germany.
Christoph Fabian LutterOrthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Germany.
Mirko RehbergUniversität zu Köln, Medizinische Fakultät und Uniklinik Köln, Klinik und Poliklinik für Kinder und Jugendmedizin, Köln, Germany.
Wolfram MittelmeierOrthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Germany.
Richard KaschOrthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Germany.
Katrin Osmanski-ZenkOrthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Germany.
Susanne FröhlichOrthopädische Klinik und Poliklinik, Universitätsmedizin Rostock, Germany.
Universitätsmedizin Rostock · DEUniversitätsmedizin Greifswald · DEUniversity of Cologne · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: With an incidence of 2-4% in all newborns, developmental dysplasia of the hip, DDH, represents the most frequent congenital disorder of the skeletal system in Germany. The therapy options are deduced with the help of a sonography. The conservative therapy approach includes the application of flexion abduction orthoses, which lead to a development of the child's hip through abduction and flexion angle. The overall structure of the orthoses puts a strain on the axial skeleton of the children. The following work is intended to clarify what role the design of the orthoses plays in this respect. Methods: Inclusion criterion for the study was fully developed newborns without an indication of skeletal malformations with Type I hip joints according to Graf verified by ultrasound. A total of 19 newborns were recruited and included in the period 3/2013-01/2015. Two types of orthoses used in treating developmental dysplasia of the hip (Tübinger splint, Otto Bock; hip flexion abduction orthosis (Superior orthosis) according to Mittelmeier-Graf, AIDAMED e.K (Kreuz et al., 2012; Mittelmeier et al., 1998; Schmitz et al., 1999), constructions differ, were used. Force was measured with the help of three force sensors, which were even able to be integrated into these without changing the design of the orthosis. In this closed system, force transmission was measured for the duration of a fixed period of two minutes. Findings: The greatest axial force development (overall force) is in the Tübinger splint with an average force of 15.1 N (min. 0.59 N, max. 53.09 N, mean 15.1, SD 2.46). 4.09 N (min. 0.96 N, max. 20.99 N, mean 4.09, SD 0.65) resulted in the Superior orthosis. Significant correlations between body weight and resulting axial traction - on average during the entire measurement period and in movement - can be taken from the statistical analysis regarding the Tübinger splint. Such a correlation cannot be depicted for the Superior orthosis. Interpretation: The analysis of the load transmission of the examined flexion and abduction orthoses reveals differences between the models. The construct of the orthoses in itself appears to play a significant role. Long-term effects of orthosis therapy on a child's axial skeleton have not been studied to date. Furthermore, it seems reasonable to expand the test series to orthoses, the design of which is configured in a similar matter compared to the examined aids. Conclusion: This study proves that the orthotic design has an influence on the infant's axial load.

Indexed as

Abduction orthosesAxial forceBiomechanicsDevelopmental hip dysplasiaMittelmeierGraf orthosisTübinger orthosis

Identifiers

PMID36478850
PMCPMC9720598
OpenAlexW4311026112

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.