Evidence map›Paper›PMID 36478678›Full record

ArticleData in brief2023

Data for: Reliability of mechanical ventilation during continuous chest compressions: A crossover study of transport ventilators in a human cadaver model of CPR.

Simon Orlob, Christoph Hobisch, Johannes Wittig, Daniel Auinger, Otto Touzil, Gabriel Honnef, Otmar Schindler, Philipp Metnitz, Georg Feigl, Gerhard Prause

Open access · goldAbstract read
In one paragraph

Article in Data in brief, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 3 countries.

Simon OrlobDivision of Anesthesiology for Cardiovascular and Thoracic Surgery and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz 8036, Austria.
Christoph HobischDivision of General Anaesthesiology, Emergency- and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz, Austria.
Johannes WittigMedical University of Graz, Neue Stiftingtalstraße 6, Graz, Austria.
Daniel AuingerDivision of General Anaesthesiology, Emergency- and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz, Austria.
Otto TouzilInstitute of Applied Information Processing and Communications, Graz University of Technology, Inffeldgasse 16a, Graz, Austria.
Gabriel HonnefDivision of General Anaesthesiology, Emergency- and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz, Austria.
Otmar SchindlerDepartment of Internal and Respiratory Medicine, Intensive Care Unit Enzenbach, State Hospital Graz II, Hörgas 30, Gratwein, Austria.
Philipp MetnitzDivision of General Anaesthesiology, Emergency- and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz, Austria.
Georg FeiglDivision of Macroscopic and Clinical Anatomy, Medical University of Graz, Harrachgasse 21, Graz, Austria.
Gerhard PrauseDivision of General Anaesthesiology, Emergency- and Intensive Care Medicine, Department of Anaesthesiology and Intensive Care Medicine, Medical University of Graz, Auenbruggerplatz 5, Graz, Austria.
Medical University of Graz · ATGraz University Hospital · ATGraz University of Technology · ATWitten/Herdecke University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The data presented in this article relate to the research article, "Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR" [1]. This article contains raw data of continuous recordings of airflow, airway and esophageal pressure during the whole experiment. Data of mechanical ventilation was obtained under ongoing chest compressions and from repetitive measurements of pressure-volume curves. All signals are presented as raw time series data with a sample rate of 200Hz for flow and 500 Hz for pressure. Additionally, we hereby publish extracted time series recordings of force and compression depth from the used automated chest compression device. Concomitantly, we report tables with time stamps from our laboratory book by which the data can be sequenced into different phases of the study protocol. We also present a dataset of derived volumes which was used for statistical analysis in our research article together with the used exclusion list. The reported dataset can help to understand mechanical properties of Thiel-embalmed cadavers better and compare different models of cardiopulmonary resuscitation (CPR). Future research may use this data to translate our findings from bench to bedside. Our recordings may become useful in developing respiratory monitors for CPR, especially in prototyping and testing algorithms of such devices.

Indexed as

BiomechanicsCardiac arrestcardiopulmonary resuscitationMechanical chest-compressionMechanical ventilationRespiratory monitoringThiel embalmed cadaver

Identifiers

PMID36478678
PMCPMC9720442
OpenAlexW4309951247

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.