Evidence map›Paper›PMID 36475583›Full record

ArticleACS applied materials & interfaces2022

Why PEDOT:PSS Should Not Be Used for Raman Sensing of Redox States (and How It Could Be).

Ivano Alessandri, Fabrizio Torricelli, Beatrice Cerea, Michele Speziani, Paolo Romele, Zsolt Miklos Kovacs-Vajna, Irene Vassalini

Abstract read
In one paragraph

Article in ACS applied materials & interfaces, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ivano AlessandriDepartment of Information Engineering, University of Brescia, via Branze 38, 25123Brescia, Italy.ORCID 0000-0003-0332-0723
Fabrizio TorricelliDepartment of Information Engineering, University of Brescia, via Branze 38, 25123Brescia, Italy.
Beatrice CereaDepartment of Information Engineering, University of Brescia, via Branze 38, 25123Brescia, Italy.
Michele SpezianiDepartment of Information Engineering, University of Brescia, via Branze 38, 25123Brescia, Italy.
Paolo RomeleDepartment of Information Engineering, University of Brescia, via Branze 38, 25123Brescia, Italy.
Zsolt Miklos Kovacs-VajnaDepartment of Information Engineering, University of Brescia, via Branze 38, 25123Brescia, Italy.
Irene VassaliniDepartment of Information Engineering, University of Brescia, via Branze 38, 25123Brescia, Italy.ORCID 0000-0002-5500-9999

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) has been recently proposed for Raman sensing of redox-active species in solution. Here, we investigated the rationale of this approach through systematic experiments, in which the Raman spectrum of PEDOT:PSS was analyzed in the presence of either nonoxidizing or oxidizing electrolytes. The results demonstrated that Raman spectra precisely reflect the conformation of PEDOT units and their interactions with PSS. Two different responses were observed. In the case of oxidizing electrolytes, the effect of charge transfer is accurately transduced in Raman spectrum changes. On the other hand, reduction induces a progressive separation between the PEDOT and PSS chains, which decreases their mutual interaction. This stimulus determines characteristic variations in the intensity, shape, and position of the Raman spectra. However, we demonstrated that the same effects can be obtained either by increasing the concentration of nonoxidizing electrolytes or by deprotonating PSS chains. This poses severe limitations to the use of PEDOT:PSS for this type of Raman sensing. This study allows us to revise most of the Raman results reported in the literature with a clear model, setting a new basis for investigating the dynamics of mixed electronic/ionic charge transfer in conductive polymers.

Indexed as

charge transferelectrolyteion diffusion dynamicsoptical sensorsPEDOT:PSSRamansaline buffers

Identifiers

PMID36475583
PMCPMC9782336

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.