Evidence map›Paper›PMID 36474986›Full record

ArticleOsteoarthritis and cartilage open2021

Avoiding unconscious injection of vial-derived rubber particles during intra-articular drug administration.

Andreas Hecker, Agostino Di Maro, Emanuel F Liechti, Frank M Klenke

Open access · goldAbstract read
In one paragraph

Article in Osteoarthritis and cartilage open, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Andreas HeckerDepartment of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 4, 3010, Bern, Switzerland.
Agostino Di MaroDepartment of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 4, 3010, Bern, Switzerland.
Emanuel F LiechtiDepartment of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 4, 3010, Bern, Switzerland.
Frank M KlenkeDepartment of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 4, 3010, Bern, Switzerland.
University of Bern · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Vial coring describes the occurrence of small rubber particles, which are formed by needles when perforating vial stoppers. These particles may be aspirated along with the drug. Unconscious injection of rubber particles may increase the risks associated with intra-articular injections. This study aimed to analyze the frequency of this phenomenon and possibilities to avoid its occurrence. Method: 800 vials of 2 ​mL, filled with sodium chloride, were divided into 4 groups (n ​= ​200 each). Aspiration through the rubber stopper was performed with a 18-Gauge needle and the fluid was ejected onto a 10 ​μm filter paper through a 18-Gauge needle (group one) and a 23-Gauge needle (group two). In group three a 23-Gauge needle was used for aspiration and ejection. In group four, aspiration was performed using 18-Gauge needles with implemented 5 ​μm filters. Subsequently, a microscopic analysis of the filter papers was performed. Results: In none of the 800 specimen, a rubber particle was detected by naked eye. Microscopically, 20 (10%) rubber particles were detected in group one, 21 (11%) in group two and 65 (33%) in group three. In group four, no particles were visualized. Conclusion: This study shows the occurrence of rubber particles in 10-33% of the cases, when standard needles are used for the aspiration of drugs. We therefore recommend using industrially prefilled syringes, filter needles or removing the rubber stopper before withdrawing drugs from vials for intra-articular injections.

Indexed as

Drug contaminationFilter needleForeign body reactionIntra-articular injectionsVial coring

Identifiers

PMID36474986
PMCPMC9718274
OpenAlexW3147077503

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.