Evidence map›Paper›PMID 36474640›Full record

ArticleWorld journal of pediatric surgery2021

Size of atrial septal defect after balloon atrial septostomy does not correlate with immediate improvement in oxygenation.

Kartik Sehgal, Kunal Sehgal, Suraj Varma

Open access · diamondAbstract read
In one paragraph

Article in World journal of pediatric surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Revisiting the Role of Balloon Atrial Septostomy Prior to the Arterial Switch Operation.World journal for pediatric & congenital heart surgery · 2024
    Article
  2. Balloon Atrial Septostomy: The Balloon Size Doesn't Matter?!CJC pediatric and congenital heart disease · 2022
    Article
  3. Balloon Atrial Septostomy: Does the Balloon Size Matter?CJC pediatric and congenital heart disease · 2022
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Kartik Sehgal *Monash University, Melbourne, Victoria, Australia.ORCID 0000-0002-1213-5127
Kunal Sehgal *Monash University, Clayton, Victoria, Australia.
Suraj VarmaMonash Heart, Monash Health, Clayton, Victoria, Australia.
Monash University · AUMonash Health · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Transposition of great arteries is a common cyanotic heart defect. Balloon atrial septostomy aims to improve circulatory mixing and oxygenation. Previous studies have combined infants with intact ventricular septum and those with ventricular septal defect. Additionally, the septostomy was performed much later after birth. The objectives were to ascertain any correlation between the atrial septal defect size and oxygenation, before and after septostomy, as well the change in parameters pre-post procedure. Methods: We performed an audit of the last 10 years of clinical and echocardiographic data (2010-2020) for infants with transposition of great arteries with intact ventricular septum. A pediatric cardiologist, masked to clinical data, reviewed the images. Results: Our study of 25 infants with transposition of great arteries with intact ventricular septum noted that the procedure was performed at a median [interquartile range (IQR)] of 3 (2, 4) hours after birth. Prostaglandin was administered to the majority of infants [20/25 (80%)]. While significant increases in partial pressure of oxygen (24±5 vs 40±6 mmHg, p<0.001) and preductal oxygen saturations (67%±18% vs 81%±11%, p=0.003) were noted, and while the atrial septal defect increased in size from 1.8±0.6 vs 4.8±0.7 mm (p<0.001), no correlation was noted between atrial septal defect size and oxygen saturations. Conclusions: In our study of infants with transposition of great arteries and intact ventricular septum managed with balloon atrial septostomy, no correlation was noted between the atrial septal defect size and oxygen saturations. Pulmonary vascular resistance and pulmonary blood flow may be important physiological variables determining oxygenation.

Indexed as

cardiologyneonatology

Identifiers

PMID36474640
PMCPMC9717414
OpenAlexW3129318749

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.