Trial reportPhysical and engineering sciences in medicine2023
Clinical validation of the Varian Truebeam intra-fraction motion review (IMR) system for prostate treatment guidance.
Trial report in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT00587990 (A Phase I/II, Randomized, Double-Blinded, Placebo-Controlled Study of the Safety and Efficacy of Intramyocardial Injection of Autologous Human Mesenchymal Stem Cells), which is not on this map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Phase I/II, Randomized, Double-Blinded, Placebo-Controlled Study of the Safety and Efficacy of Intramyocardial Injection of Autologous Human Mesenchymal Stem Cells (MSCs) in Patients With Chronic Ischemic Left Ventricular Dysfunction Secondary to Myocardial Infarction (MI) Undergoing Cardiac Surgery for Coronary Artery Bypass Grafting (CABG)
Who cites it
4 citing papers in PubMed.
- Cone-beam CT-based estimations of prostate motion and dose distortion during radiotherapy.Physics and imaging in radiation oncology · 2025Article
- Exploring the Use of Contour-Based Intrafraction Motion Review for Spine Stereotactic Body Radiation Therapy Treatments.Advances in radiation oncology · 2024Article
- Impact of technological advances in treatment planning, image guidance, and treatment delivery on target margin design for prostate cancer radiotherapy: an updated review.The British journal of radiology · 2024Review
- Dynamic intrafractional position monitoring with implanted fiducial markers for enhanced accuracy in radiotherapy of prostate cancer.Physical and engineering sciences in medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study quantified the performance of Intra-fraction Motion Review (IMR) during prostate Stereotactic Body Radiotherapy (SBRT) treatments. IMR was evaluated using prostate motion data from patients treated in an SBRT clinical trial (PROMETHEUS, NCT00587990).IMR measured prostate displacements were compared to those of two 3D motion management methods: Kilovoltage Intra-fraction Motion management (KIM) and MV/kV triangulation. A planning study assessing the impact of a defined prostate motion (2-5 mm) on the PTV coverage with and without IMR was performed. A clinically relevant IMR search region for prostate cancer SBRT treatments was determined using a customised anthropomorphic pelvis phantom with implanted gold seeds and a motion platform. IMR showed submillimeter agreement with corresponding 2D projections from both KIM and MV/kV triangulation. However, IMR detected actual displacements consistently in considerably fewer frames than KIM (3D), with the actual numbers depending on the settings. The Default Search Region (DSR) method employing a circular search region proved superior to user-contoured structures in detecting clinically relevant prostate motion. Reducing the DSR search region radius can reduce the impact of the 2D nature of IMR and improve the detectability of actual motion (by 10% per 0.5 mm reduction) but must be balanced against increased beam interruptions from minor, clinically irrelevant motion. The use of IMR for SBRT prostate treatments has the potential to improve target dose coverage (minimum dose to 98% of the PTV, D98%) by > 20% compared to treatment without IMR. Calculated D98% of IMR monitored treatments with motion was within 1.5% of plans without motion.
Indexed as
Identifiers
36472802What OpenQuestion holds
Registered trials