Evidence map›Paper›PMID 36471345›Full record

SynthesisJournal of orthopaedic surgery and research2022

TiRobot‑assisted versus conventional fluoroscopy-assisted percutaneous sacroiliac screw fixation for pelvic ring injuries: a meta‑analysis.

Chunpeng Zhao, Gang Zhu, Yu Wang, Xinbao Wu

Registry-linked trialAbstract readMeta-Analysis
In one paragraph

Synthesis in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07738458 (Robot-Assisted Closed Reduction and Internal Fixation for Intertrochanteric Femoral Fractures), which is not on this map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07738458 narecruitingnot on this mapstarted 2026, after this paper: background citation

Robot-Assisted Closed Reduction and Internal Fixation for Intertrochanteric Femoral Fractures: A Randomized Controlled Trial

TypeinterventionalSponsorBeijing Jishuitan HospitalRan2026 to 2028Enrolled60ConditionsIntertrochanteric Fractures, Intertrochanteric Fractures of the Hip, Intertrochanteric Fractures of the FemurArmsRobot-assisted closed reduction and internal fixation, Conventional manual closed reduction and internal fixation
3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Ten-Year Trends in Pelvic Fractures Among China's Aging Population: A Retrospective Single-Center Study.Medical science monitor : international medical journal of experimental and clinical research · 2025
    Article
  6. Article
  7. [Effectiveness analysis of 5G remote robotic surgery in pelvic fracture treatment].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Article
  8. Article
  9. Percutaneous endoscopic lumbar partial laminectomy assisted by a new miniature parallel surgical robot system: a trial on a cadaveric specimen.Wideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques · 2025
    Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chunpeng ZhaoDepartment of Orthopedics and Traumatology, Beijing Jishuitan Hospital, Beijing, 100035, China.
Gang ZhuRossum Robot Co., Ltd., Beijing, 100083, China.
Yu WangSchool of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China.
Xinbao WuDepartment of Orthopedics and Traumatology, Beijing Jishuitan Hospital, Beijing, 100035, China. imc7788@163.com.

Funding

Beijing Science and Technology Planning Project Z201100005420033National Natural Science Foundation of China NSFC61871019Natural Science Foundation of Beijing Municipality 19L2011
6 · The paper itself

Abstract

backgroundThe TiRobot is the only robot that has been reported in the literature for posterior pelvic injuries. We aim to compare TiRobot-assisted pelvic screw fixation with the conventional fluoroscopy-assisted percutaneous sacroiliac screw fixation.

methodsWe conducted a meta-analysis to identify studies involving TiRobot‑assisted versus conventional percutaneous sacroiliac screw fixation for pelvic ring injuries in electronic databases, including Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and WanFang database, up to April 2022. The following keywords were used: "TiRobot," "robot," "robotic," "pelvic fracture," "screw fixation," "percutaneous," and "pelvic ring injury." Pooled effects of this meta-analysis were calculated using STATA SE version 15.0.

resultsCompared with conventional fluoroscopy-assisted percutaneous sacroiliac screw fixation, TiRobot will result in less radiation exposure time of screw implantation (P = 0.000), less frequency of intraoperative fluoroscopy (P = 0.000), fewer guide wire attempts (P = 0.000), less intraoperative blood loss (P = 0.005), better screw accuracy (P = 0.011), better Majeed score (P = 0.031), and higher overall excellent and good rates of Majeed score (P = 0.018). However, there were no significant differences in terms of operative time (P = 0.055), fracture healing time (P = 0.365), and overall excellent and good rate of reduction accuracy (P = 0.426) between the two groups.

conclusionTiRobot-assisted fixation has less intraoperative fluoroscopy and intraoperative blood loss, superior screw accuracy, and Majeed score compared with conventional percutaneous sacroiliac screw fixation. TiRobot has no significant effect on operative time, fracture healing time, and reduction accuracy. Given the relevant possible biases in our meta-analysis, we required more adequately powered and better-designed RCT studies with long-term follow-up to reach a firmer conclusion.

Indexed as

Fractures, BonePelvic BonesBlood Loss, SurgicalBone ScrewsFluoroscopyFracture Fixation, InternalHumansRetrospective StudiesPelvic fracturePercutaneous screw fixationRobot-assistedTiRobot

Identifiers

PMID36471345
PMCPMC9721051

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.