Evidence map›Paper›PMID 36471171›Full record

ArticleInsights into imaging2022

Integrity of personal radiation protective equipment (PRPE): a 4-year longitudinal follow-up study.

Pieter-Jan Kellens, An De Hauwere, Tim Gossye, Sven Peire, Ingrid Tournicourt, Luc Strubbe, Jan De Pooter, Klaus Bacher

Open access · goldAbstract read
In one paragraph

Article in Insights into imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Pieter-Jan KellensMedical Physics, Ghent University, Proeftuinstraat 86, 9000, Ghent, Belgium. PieterJan.Kellens@UGent.be.ORCID http://orcid.org/0000-0001-9289-8812
An De HauwereMedical Physics, Ghent University, Proeftuinstraat 86, 9000, Ghent, Belgium.
Tim GossyeMedical Physics, Ghent University, Proeftuinstraat 86, 9000, Ghent, Belgium.
Sven PeireAZ Sint-Jan Brugge - Oostende AV, Brugge, Belgium.
Ingrid TournicourtAZ Sint-Jan Brugge - Oostende AV, Brugge, Belgium.
Luc StrubbeAZ Sint-Jan Brugge - Oostende AV, Brugge, Belgium.
Jan De PooterHeart Centre, University Hospital Ghent, Ghent, Belgium.
Klaus BacherMedical Physics, Ghent University, Proeftuinstraat 86, 9000, Ghent, Belgium.
AZ Sint-Jan · BEGhent University · BEGhent University Hospital · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPersonal radiation protective equipment (PRPE) such as lead aprons minimises radiation exposure of operators using X-ray systems. However, PRPE might be prone to cracks in the attenuating layer resulting in inadequate radiation protection. This study aims to investigate the prevalence, qualification and quantification of PRPE integrity during a longitudinal follow-up study.

methodsAll PRPE of a large, general hospital was evaluated yearly in the period 2018-2021. The equipment was inspected on a tele-operated X-ray table, and tears were qualified and quantified using an X-ray opaque ruler. Rejection criteria of Lambert & McKeon, with an extra rejection criterion of 15 mm

resultsOver the 4-year follow-up period, a total of 1011 pieces of PRPE were evaluated. In total, 47.3% of the PRPE showed tears of which 31% exceeded the mentioned rejection criteria. Remarkably, of the 287 newly registered pieces of PRPE, 6.0% showed tears in the first year of use of which 88.2% needed to be rejected. Also, 48% of the repaired PRPE was rejected again in the consecutive year.

conclusionsPRPE is prone to cracks. Up to 50% of PRPE showed tears and cracks resulting in 31% rejections. Newly purchased PRPE is not guaranteed to remain free of cracks and tears in the first year of use. Repair does not guarantee a long-term solution for prolonging the lifespan. Regular X-ray-based integrity analysis of PRPE is needed to ensure adequate radioprotection for operators using X-ray systems.

Indexed as

Integrity defectsPRPEQuality assuranceRadioprotection

Identifiers

PMID36471171
PMCPMC9723036
OpenAlexW4310780168

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.