Evidence map›Paper›PMID 36470881›Full record

ArticleScientific reports2022

Blood flow but not cannula positioning influences the efficacy of Veno-Venous ECMO therapy.

Massimiliano Leoni, Johannes Szasz, Jens Meier, Luca Gerardo-Giorda

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.1field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Massimiliano LeoniJohann Radon Institute for Computational and Applied Mathematics, Linz, Austria.
Johannes SzaszDepartment of Anaesthesiology and Intensive Care, Kepler University Klinikum, Linz, Austria.
Jens MeierDepartment of Anaesthesiology and Intensive Care, Kepler University Klinikum, Linz, Austria.
Luca Gerardo-GiordaJohann Radon Institute for Computational and Applied Mathematics, Linz, Austria. luca.gerardo-giorda@jku.at.
Kepler Universitätsklinikum · ATJohannes Kepler University of Linz · ATJohann Radon Institute for Computational and Applied Mathematics · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Despite being vital in treating intensive-care patients with lung failure, especially COVID-19 patients, Veno-Venous Extra-Corporeal Membrane Oxygenation does not exploit its full potential, leaving ample room for improvement. The objective of this study is to determine the effect of cannula positioning and blood flow on the efficacy of Veno-Venous Extra-Corporeal Membrane Oxygenation, in particular in relationship with blood recirculation. We performed 98 computer simulations of blood flow and oxygen diffusion in a computerized-tomography-segmented right atrium and venae cavae for different positions of the returning and draining cannulae and ECMO flows of 3 L/min and [Formula: see text]. For each configuration we measured how effective Veno-Venous Extra-Corporeal Membrane Oxygenation is at delivering oxygen to the right ventricle and thus to the systemic circulation. The main finding is that VV-ECMO efficacy is largely affected by the ECMO flow (global peak blood saturation: [Formula: see text]; average inter-group saturation gain: 9 percentage points) but only scarcely by the positioning of the cannulae (mean saturation ± standard deviation for the 3 L/min case: [Formula: see text]; for the [Formula: see text] case: [Formula: see text]). An important secondary outcome is that recirculation, more intense with a higher ECMO flow, is less detrimental to the procedure than previously thought. The efficacy of current ECMO procedures is intrinsically limited and fine-tuning the positions of the cannulae, risking infections, offers very little gain. Setting a higher ECMO flow offers the biggest benefit despite mildly increasing blood recirculation.

Indexed as

COVID-19Extracorporeal Membrane OxygenationCannulaHemodynamicsHumansOxygenOxygen

Identifiers

PMID36470881
PMCPMC9722702
OpenAlexW4310775546

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.