Evidence map›Paper›PMID 36469151›Full record

ArticleEJNMMI physics2022

A novel intelligent radiomic analysis of perfusion SPECT/CT images to optimize pulmonary embolism diagnosis in COVID-19 patients.

Sonia Baeza, Debora Gil, Ignasi Garcia-Olivé, Maite Salcedo-Pujantell, Jordi Deportós, Carles Sanchez, Guillermo Torres, Gloria Moragas, Antoni Rosell

Erratum issuedAbstract read
In one paragraph

Article in EJNMMI physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors.

Sonia BaezaRespiratory Medicine Department, Hospital Universitari Germans Trias I Pujol, Badalona, Barcelona, Spain. smbaeza.germanstrias@gencat.cat.ORCID http://orcid.org/0000-0001-6612-6018
Debora GilComputer Vision Center and Computer Science Department, UAB, Barcelona, Spain.
Ignasi Garcia-OlivéRespiratory Medicine Department, Hospital Universitari Germans Trias I Pujol, Badalona, Barcelona, Spain.
Maite Salcedo-PujantellNuclear Medicine Department, Hospital Universitari Germans Trias I Pujol, Badalona, Barcelona, Spain.
Jordi DeportósNuclear Medicine Department, Hospital Universitari Germans Trias I Pujol, Badalona, Barcelona, Spain.
Carles SanchezComputer Vision Center and Computer Science Department, UAB, Barcelona, Spain.
Guillermo TorresComputer Vision Center and Computer Science Department, UAB, Barcelona, Spain.
Gloria MoragasNuclear Medicine Department, Hospital Universitari Germans Trias I Pujol, Badalona, Barcelona, Spain.
Antoni RosellRespiratory Medicine Department, Hospital Universitari Germans Trias I Pujol, Badalona, Barcelona, Spain.

Funding

Barcelona Respiratory Networks - Fundació Ramón Pla 2020Fundació Acadèmia Ciències Mèdiques de Catalunya i de Balears 2020Fundació Catalunya-La Pedrera 2020Lung ambition alliance 2021Ministerio de Economía, Industria y Competitividad, Gobierno de España RTI2018-095209-B-C21-22
6 · The paper itself

Abstract

backgroundCOVID-19 infection, especially in cases with pneumonia, is associated with a high rate of pulmonary embolism (PE). In patients with contraindications for CT pulmonary angiography (CTPA) or non-diagnostic CTPA, perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) is a diagnostic alternative. The goal of this study is to develop a radiomic diagnostic system to detect PE based only on the analysis of Q-SPECT/CT scans.

methodsThis radiomic diagnostic system is based on a local analysis of Q-SPECT/CT volumes that includes both CT and Q-SPECT values for each volume point. We present a combined approach that uses radiomic features extracted from each scan as input into a fully connected classification neural network that optimizes a weighted cross-entropy loss trained to discriminate between three different types of image patterns (pixel sample level): healthy lungs (control group), PE and pneumonia. Four types of models using different configuration of parameters were tested.

resultsThe proposed radiomic diagnostic system was trained on 20 patients (4,927 sets of samples of three types of image patterns) and validated in a group of 39 patients (4,410 sets of samples of three types of image patterns). In the training group, COVID-19 infection corresponded to 45% of the cases and 51.28% in the test group. In the test group, the best model for determining different types of image patterns with PE presented a sensitivity, specificity, positive predictive value and negative predictive value of 75.1%, 98.2%, 88.9% and 95.4%, respectively. The best model for detecting pneumonia presented a sensitivity, specificity, positive predictive value and negative predictive value of 94.1%, 93.6%, 85.2% and 97.6%, respectively. The area under the curve (AUC) was 0.92 for PE and 0.91 for pneumonia. When the results obtained at the pixel sample level are aggregated into regions of interest, the sensitivity of the PE increases to 85%, and all metrics improve for pneumonia.

conclusionThis radiomic diagnostic system was able to identify the different lung imaging patterns and is a first step toward a comprehensive intelligent radiomic system to optimize the diagnosis of PE by Q-SPECT/CT. HIGHLIGHTS: Artificial intelligence applied to Q-SPECT/CT is a diagnostic option in patients with contraindications to CTPA or a non-diagnostic test in times of COVID-19.

Indexed as

COVID-19CTNeural networksPulmonary embolismRadiomicsSPECT

Identifiers

PMID36469151
PMCPMC9905449

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.