ArticlePhotoacoustics2022
Improving photoacoustic imaging in low signal-to-noise ratio by using spatial and polarity coherence.
Article in Photoacoustics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Improved quantification of photoacoustic biomarkers through residual-based noise masking.Photoacoustics · 2026Article
- Enhancing image reconstruction in photoacoustic imaging using spatial coherence mean-to-standard-deviation factor beamforming.Biomedical optics express · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To suppress the noise and sidelobe of photoacoustic images, a method is proposed combined with spatial coherence and polarity coherence. In this method, PA signals are delayed, multiplied, then performed polarity coherence, and finally summed. The polarity of delayed-and-multiplied signals rather than the amplitude is considered in polarity coherence operation. The polarity coherence factor is calculated based on the standard deviation of the polarity. Then, the factor as weights is applied to the coherent sum output after spatial autocorrelation to finally obtain the image. The simulated and experimental results prove that the noise level can be effectively suppressed due to its relatively low polarity coherence factor. Compared with the delay-and-sum method, the quantitative results in simulations show that the image contrast and full-width at half-maximum of the proposed method increase by about 227.0 % and 56.5 % when the signal-to-noise ratio of the raw signal is 0 dB, respectively. Besides achieving a better image contrast, this method obtains improvements in sidelobe attenuation and has a narrow main lobe.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.