Evidence map›Paper›PMID 36465994›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering

No-gold-standard evaluation of quantitative imaging methods in the presence of correlated noise.

Ziping Liu, Zekun Li, Joyce C Mhlanga, Barry A Siegel, Abhinav K Jha

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. On Hallucinations in Artificial Intelligence-Generated Content for Nuclear Medicine Imaging (the DREAM Report).Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
    Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Need for objective task-based evaluation of AI-based segmentation methods for quantitative PET.Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ziping LiuDepartment of Biomedical Engineering, Washington University, St. Louis, MO, USA.
Zekun LiDepartment of Biomedical Engineering, Washington University, St. Louis, MO, USA.
Joyce C MhlangaMallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA.
Barry A SiegelMallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA.
Abhinav K JhaDepartment of Biomedical Engineering, Washington University, St. Louis, MO, USA.

Funding

A no-gold-standard framework to objectively evaluate quantitative imaging methods with patient dataR01EB031051 · NIBIB · WASHINGTON UNIVERSITY · PI JHA, ABHINAV K · 2021 to 2025
$2.1M
A fully automated PET radiomics frameworkR56EB028287 · NIBIB · WASHINGTON UNIVERSITY · PI JHA, ABHINAV K · 2021 to 2021
$493k
Transmission-less attenuation and scatter compensation in myocardial perfusion SPECT with list-mode dataR21EB024647 · NIBIB · WASHINGTON UNIVERSITY · PI JHA, ABHINAV K · 2018 to 2019
$430k
NIBIB NIH HHS R01 EB031051NIBIB NIH HHS R21 EB024647NIBIB NIH HHS R56 EB028287
6 · The paper itself

Abstract

Objective evaluation of quantitative imaging (QI) methods with patient data is highly desirable, but is hindered by the lack or unreliability of an available gold standard. To address this issue, techniques that can evaluate QI methods without access to a gold standard are being actively developed. These techniques assume that the true and measured values are linearly related by a slope, bias, and Gaussian-distributed noise term, where the noise between measurements made by different methods is independent of each other. However, this noise arises in the process of measuring the same quantitative value, and thus can be correlated. To address this limitation, we propose a no-gold-standard evaluation (NGSE) technique that models this correlated noise by a multi-variate Gaussian distribution parameterized by a covariance matrix. We derive a maximum-likelihood-based approach to estimate the parameters that describe the relationship between the true and measured values, without any knowledge of the true values. We then use the estimated slopes and diagonal elements of the covariance matrix to compute the noise-to-slope ratio (NSR) to rank the QI methods on the basis of precision. The proposed NGSE technique was evaluated with multiple numerical experiments. Our results showed that the technique reliably estimated the NSR values and yielded accurate rankings of the considered methods for 83% of 160 trials. In particular, the technique correctly identified the most precise method for ∼ 97% of the trials. Overall, this study demonstrates the efficacy of the NGSE technique to accurately rank different QI methods when correlated noise is present, and without access to any knowledge of the ground truth. The results motivate further validation of this technique with realistic simulation studies and patient data.

Indexed as

medical imagingno-gold-standardobjective evaluationquantitative imaging

Identifiers

PMID36465994
PMCPMC9717481

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.