Evaluation of Three Human-Use Glucometers for Blood Glucose Measurement in Dogs.

Matheus Albuquerque Basilio Dos Santos, Alesssandra Martins Vargas, Paula Nunes Rosato, Carolina Gomes Andrade, Camila Marinelli Martins, Giuliana Petri

Open access · goldAbstract read
In one paragraph

Article in Veterinary medicine international, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Impact on result interpretation of correct and incorrect selection of veterinary glucometer canine and feline settings.Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Matheus Albuquerque Basilio Dos SantosMetropolitan University of Santos (UNIMES)-Prefeito Antônio Manoel de Carvalho Avenue, 3935 Morro Nova Cintra 11080-100, Santos, Sao Paulo, Brazil.ORCID https://orcid.org/0000-0002-8579-3649
Alesssandra Martins VargasCollege Anclivepa Ulisses Cruz Avenue, 285 Tatuapé 03077-000, Santos, Sao Paulo, Brazil.
Paula Nunes RosatoAnclivet Veterinary Laboratory Goias Street, 118, Gonzaga 11050-100, Santos, Sao Paulo, Brazil.
Carolina Gomes AndradeSão Judas Tadeu University Comendador Martins Street, 52, Vila Matias, 11015-530, Santos, Sao Paulo, Brazil.
Camila Marinelli MartinsAAC&T Research Consulting LTDA Domingas Vigo Zaninelli Street, Boa Vista 82540-096, Curitiba, Parana, Brazil.
Giuliana PetriMetropolitan University of Santos (UNIMES)-Prefeito Antônio Manoel de Carvalho Avenue, 3935 Morro Nova Cintra 11080-100, Santos, Sao Paulo, Brazil.
Universidade Metropolitana de Santos · BRUniversidade São Judas Tadeu · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Glucometers or portable sensors are used to quickly measure blood glucose at low cost. They are used in veterinary practice and by guardians to monitor diseases that require, as in diabetes mellitus. However, not all commercially available glucometers (human and veterinary) are suitable for this purpose. Methods: The portable glucometers are the FreeStyle Freedom Lite®, FreeStyle Optium Neo®, and On Call Plus® models. Glucometer results were compared with the enzymatic colorimetric glucose oxidase laboratory reference method. Using descriptive and comparative statistical analysis, there were correlations between these devices and the standard method, ISO 15197 : 2003 and ISO 15197 : 2013 standards, and error grid analysis. Results: Only the Freedom Lite® device observed a statistical difference when compared with the reference method. Despite the underestimated glucose concentrations assessed with humane devices, all three tested herein showed a positive coefficient. However, none of these achieved all ISO guidelines.

Identifiers

PMID36465855
PMCPMC9715321
OpenAlexW4309905533

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.