Evidence map›Paper›PMID 36464272›Full record

ArticleExperimental animals2023

Construction of a canine model with acute type B aortic dissection using a self-made pressure-driven flow device.

Zongwei Liu, Jiaxue Bi, Fang Niu, Hao Liang, Jibo Fan, Jiajun Li, Duan Wang, Xiangchen Dai

Open access · diamondAbstract read
In one paragraph

Article in Experimental animals, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Zongwei LiuDepartment of Vascular Surgery of Tianjin Medical University General Hospital, No. 154 Anshan Road, Heping District, Tianjin, 300000, P.R. China.
Jiaxue BiDepartment of Vascular Surgery of Tianjin Medical University General Hospital, No. 154 Anshan Road, Heping District, Tianjin, 300000, P.R. China.
Fang NiuDepartment of Vascular Surgery of Tianjin Medical University General Hospital, No. 154 Anshan Road, Heping District, Tianjin, 300000, P.R. China.
Hao LiangDepartment of Vascular Surgery of Tianjin Medical University General Hospital, No. 154 Anshan Road, Heping District, Tianjin, 300000, P.R. China.
Jibo FanDepartment of Vascular Surgery of Tianjin Medical University General Hospital, No. 154 Anshan Road, Heping District, Tianjin, 300000, P.R. China.
Jiajun LiDepartment of Vascular Surgery of Tianjin Medical University General Hospital, No. 154 Anshan Road, Heping District, Tianjin, 300000, P.R. China.
Duan WangDepartment of Vascular Surgery of Tianjin Medical University General Hospital, No. 154 Anshan Road, Heping District, Tianjin, 300000, P.R. China.
Xiangchen DaiDepartment of Vascular Surgery of Tianjin Medical University General Hospital, No. 154 Anshan Road, Heping District, Tianjin, 300000, P.R. China.
Tianjin Medical University General Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A reproducible canine aortic dissection (AD) model would be useful for evaluating the performance of novel endovascular treatment devices. Therefore, we attempted to create a reproducible canine model of Stanford type B AD (TBAB) by a surgical method. Computed tomography angiography was performed 2 h after the procedure to determine if a false lumen was present, and follow-up imaging was performed 10 d after the procedure using digital subtraction angiography, intravascular ultrasound (IVUS), and color Doppler flow imaging (CDFI) to confirm stable persistence of the false lumen. The success rate of model construction was 88.8% (16/18). All surviving dogs had distal re-entries (16/16). The number of re-entries in the dogs was 1.50 ± 0.52, and the mean length of the false lumen was 175.37 ± 16.98 mm. IVUS showed the area of the false lumen at the narrowest part of the arterial lumen was 84.88 ± 1.27%. The CDFI showed that the peak systolic velocity in the false lumen (10.89 ± 0.74 cm/s) was significantly slower than that in the true lumen (25.31 ± 1.72 cm/s; P<0.001). Moreover, the direction of blood flow in the true lumen was consistent, whereas that in the false lumen was disordered. We optimized the traditional surgical method to construct a canine model of TBAD to improve the success rate of model construction, and designed a novel device to lengthen the false lumen. The proposed model has wide implications in evaluating the performance of novel endovascular treatment devices and studying the AD-related hemodynamics.

Indexed as

Aortic DissectionBlood Vessel Prosthesis ImplantationAnimalsDogsHemodynamicsStentsTomography, X-Ray ComputedTreatment Outcomecanine modelself-made pressure-driven water flow deviceStanford type B aortic dissection

Identifiers

PMID36464272
PMCPMC10202717
OpenAlexW4310701542

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.