ArticleJournal of clinical monitoring and computing2023
Agreement of somatic and renal near-infrared spectroscopy with reference blood samples during a controlled hypoxia sequence: a healthy volunteer study.
Article in Journal of clinical monitoring and computing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Single-Center, Prospective Study in Healthy Volunteers for Validation of the O3 Regional Somatic Tissue Oxygenation Monitor
Intraoperative Multimodal Monitoring as a Means in Reducing the Duration of Mechanical Ventilation in High-Risk Patients Undergoing Major Abdominal Procedures - A Pilot Study
Who cites it
6 citing papers in PubMed.
- Intraoperative renal and cerebral tissue oxygen saturation measurements to predict postoperative acute kidney injury in pediatric cardiac surgery: a prospective observational study.Journal of clinical monitoring and computing · 2026Observational
- Reliability of diffuse optical spectroscopies for evaluation of cerebral hemometabolic stress in children with sickle cell anemia.Biomedical optics express · 2026Article
- Renal Metabolic Rate of Oxygen in Response to Hypoxia Challenges by Means of Quantitative MRI in Humans.NMR in biomedicine · 2025Article
- MRI-based quantification of whole-organ renal metabolic rate of oxygen during free-breathing.Magnetic resonance in medicine · 2025Article
- Quantification of whole-organ individual and bilateral renal metabolic rate of oxygen.Magnetic resonance in medicine · 2024Article
- MRI-based quantification of whole-organ renal metabolic rate of oxygen.NMR in biomedicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeO3® Regional Oximetry (Masimo Corporation, California, USA) is validated for cerebral oximetry. We aimed to assess agreement of somatic and renal near-infrared spectroscopy with reference blood samples.
methodsO3 sensors were placed bilaterally on the quadriceps and flank of 26 healthy volunteers. A stepped, controlled hypoxia sequence was performed by adding a mixture of nitrogen and room air to the breathing circuit. O3-derived oxygen saturation values were obtained at baseline and at six decremental saturation levels (5% steps). Blood samples (radial artery, iliac vein (somatic reference) and renal vein) were obtained at each step. Reference values were calculated as: 0.7 × venous saturation + 0.3 × arterial saturation. The agreement between O3-derived values with blood reference values was assessed by calculating root-mean-square error accuracy and Bland-Altman plots.
resultsThe root-mean-square error accuracy was 6.0% between quadriceps oxygen saturation and somatic reference values. The mean bias was 0.8%, with limits of agreement from -7.7 to 9.3%. These were 5.1% and 0.6% (-8.3 to 9.5%) for flank oxygen saturation and somatic reference values, respectively, and 7.7% and -4.9% (-15.0 to 5.2%) for flank oxygen saturation and renal reference values. The kidney depth was 3.1 ± 0.9 cm below the skin.
conclusionO3 regional oximetry can be used on the quadriceps and flank to monitor somatic saturation, yet has a saturation-level dependent bias. O3-derived values obtained at the flank underestimated renal reference values. Additionally, it is unlikely that the flank sensors did directly measure renal tissue.
trial registrationClinicaltrials.gov (NCT04584788): registered October 6th, 2020.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials