Evidence map›Paper›PMID 36459599›Full record

ArticleIEEE transactions on medical imaging2023

Segmentation-Free PVC for Cardiac SPECT Using a Densely-Connected Multi-Dimensional Dynamic Network.

Huidong Xie, Zhao Liu, Luyao Shi, Kathleen Greco, Xiongchao Chen, Bo Zhou, Attila Feher, John C Stendahl, Nabil Boutagy, Tassos C Kyriakides and 3 more

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. AI in SPECT Imaging: Opportunities and Challenges.Seminars in nuclear medicine · 2025
    Review
  5. Article
  6. A Deep-Learning-Based Partial-Volume Correction Method for QuantitativeJournal of nuclear medicine : official publication, Society of Nuclear Medicine · 2024
    Article
  7. Unified Noise-aware Network for Low-count PET Denoising with Varying Count Levels.IEEE transactions on radiation and plasma medical sciences · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 2 institutions in 1 country.

Huidong Xie
Zhao Liu
Luyao Shi
Kathleen Greco
Xiongchao Chen
Bo Zhou
Attila Feher
John C Stendahl
Nabil Boutagy
Tassos C Kyriakides
Ge Wang
Albert J Sinusas
Chi Liu
Yale University · USRensselaer Polytechnic Institute · US

Funding

Yale Clinical and Translational Science Award (U Component)UL1TR001863 · NCATS · YALE UNIVERSITY · PI John H. Krystal, LUCILA OHNO-MACHADO · 2016 to 2026
$102.9M
Training In Multi-modality Molecular & Translational Cardiovascular ImagingT32HL098069 · NHLBI · YALE UNIVERSITY · PI JAMES S DUNCAN, Georges El Fakhri · 2010 to 2026
$5.2M
Development of advanced cardiac SPECT imaging technologiesR01HL154345 · NHLBI · YALE UNIVERSITY · PI LIU, CHI, SINUSAS, ALBERT J · 2020 to 2023
$3.2M
Low-dose SPECT/CT for imaging chemotherapy-induced microvascular cardiotoxicityR01HL123949 · NHLBI · YALE UNIVERSITY · PI LIU, CHI · 2014 to 2018
$3.2M
Hybrid Volumetric SPECT/CT Imaging SystemS10RR025555 · NCRR · YALE UNIVERSITY · PI SINUSAS, ALBERT J · 2009 to 2009
$500k
NCATS NIH HHS UL1 TR001863NCRR NIH HHS S10 RR025555NHLBI NIH HHS R01 HL123949NHLBI NIH HHS R01 HL154345NHLBI NIH HHS T32 HL098069
6 · The paper itself

Abstract

In nuclear imaging, limited resolution causes partial volume effects (PVEs) that affect image sharpness and quantitative accuracy. Partial volume correction (PVC) methods incorporating high-resolution anatomical information from CT or MRI have been demonstrated to be effective. However, such anatomical-guided methods typically require tedious image registration and segmentation steps. Accurately segmented organ templates are also hard to obtain, particularly in cardiac SPECT imaging, due to the lack of hybrid SPECT/CT scanners with high-end CT and associated motion artifacts. Slight mis-registration/mis-segmentation would result in severe degradation in image quality after PVC. In this work, we develop a deep-learning-based method for fast cardiac SPECT PVC without anatomical information and associated organ segmentation. The proposed network involves a densely-connected multi-dimensional dynamic mechanism, allowing the convolutional kernels to be adapted based on the input images, even after the network is fully trained. Intramyocardial blood volume (IMBV) is introduced as an additional clinical-relevant loss function for network optimization. The proposed network demonstrated promising performance on 28 canine studies acquired on a GE Discovery NM/CT 570c dedicated cardiac SPECT scanner with a 64-slice CT using Technetium-99m-labeled red blood cells. This work showed that the proposed network with densely-connected dynamic mechanism produced superior results compared with the same network without such mechanism. Results also showed that the proposed network without anatomical information could produce images with statistically comparable IMBV measurements to the images generated by anatomical-guided PVC methods, which could be helpful in clinical translation.

Indexed as

AlgorithmsTomography, Emission-Computed, Single-PhotonAnimalsArtifactsCardiac Imaging TechniquesDogsErythrocytes

Identifiers

PMID36459599
PMCPMC10204821
OpenAlexW4283640977

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.