Anodic Polarity Minimizes Facial Nerve Stimulation as a Side Effect of Cochlear Implantation.

Wiebke S Konerding, Peter Baumhoff, Andrej Kral

Open access · hybridAbstract read
In one paragraph

Article in Journal of the Association for Research in Otolaryngology : JARO, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. An Electrically Evoked Compound Action Potential Marker for Local Spiral Ganglion Neuron Degeneration: The Failure Index.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2025
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Wiebke S KonerdingDepartment of Experimental Otology, Hannover Medical School, Nife Stadtfelddamm 34, 30559, Hannover, Germany. konerding.wiebke@mh-hannover.de.ORCID 0000-0003-2758-6497
Peter BaumhoffDepartment of Experimental Otology, Hannover Medical School, Nife Stadtfelddamm 34, 30559, Hannover, Germany.ORCID 0000-0003-0632-9715
Andrej KralDepartment of Experimental Otology, Hannover Medical School, Nife Stadtfelddamm 34, 30559, Hannover, Germany.ORCID 0000-0002-7762-4642
Medizinische Hochschule Hannover · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

One severe side effect of the use of cochlear implants (CI) is coincidental facial nerve stimulation (FNS). Clinical methods to alleviate FNS range from the reprogramming of processor settings to revision surgery. We systematically assessed different changes in CI stimulation modes that have been discussed in the literature as "rescue factors" from FNS: electrode configuration (broad to focused), pulse shape (symmetric biphasic to pseudo-monophasic), and pulse polarity (cathodic to anodic). An FNS was assessed, based on electrophysiological thresholds, in 204 electrically evoked compound action potential (eCAP) input/output functions recorded from 33 ears of 26 guinea pigs. The stimulation level difference between auditory nerve eCAP threshold and FNS threshold was expressed as the eCAP-to-FNS offset. Coincidental FNS occurred in all animals and in 45% of all recordings. A change from monopolar to focused (bipolar, tripolar) configurations minimized FNS. The Euclidean distance between the CI contacts and the facial nerve explained no more than 33% of the variance in FNS thresholds. For both the FNS threshold and the eCAP-to-FNS offset, the change from cathodic to anodic pulse polarity significantly reduced FNS and permitted a gain of 14-71% of the dynamic range of the eCAP response. This "anodic rescue effect" was stronger for pseudo-monophasic pulses as compared to the symmetric biphasic pulse shape. These results provide possible mechanisms underlying recent clinical interventions to alleviate FNS. The "anodic-rescue effect" may offer a non-invasive therapeutic option for FNS in human CI users that should be tested clinically, preferably in combination with current-focusing methods.

Indexed as

Cochlear ImplantationCochlear ImplantsAction PotentialsAnimalsCochleaCochlear NerveElectric StimulationEvoked PotentialsEvoked Potentials, AuditoryFacial NerveGuinea PigsHumansCochlear implantElectrically evoked compound action potentialFacial nerve stimulationPolarity effect

Identifiers

PMID36459250
PMCPMC9971531
OpenAlexW4310603081

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked