Evidence map›Paper›PMID 36459144›Full record

ArticleJournal of biomechanical engineering2023

A Computational Study of Dynamic Obstruction in Type B Aortic Dissection.

T Kim, P A J van Bakel, N Nama, N Burris, H J Patel, D M Williams, C A Figueroa

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.5field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

T KimDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48105.
P A J van BakelDepartment of Cardiac Surgery, University of Michigan, Ann Arbor, MI 48105.
N NamaDepartment of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, NE 68588.
N BurrisDepartment of Radiology, University of Michigan, Ann Arbor, MI 48105.
H J PatelDepartment of Cardiac Surgery, University of Michigan, Ann Arbor, MI 48105.
D M WilliamsDepartment of Radiology, University of Michigan, Ann Arbor, MI 48105.
C A FigueroaDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48105; Department of Surgery, University of Michigan, Ann Arbor, MI 48105.
University of Michigan–Ann Arbor · USUniversity of Nebraska–Lincoln · US

Funding

Vascular Deformation Mapping (VDM) for Automated, 3D Assessment of Thoracic Aortic AneurysmR44HL145953 · NHLBI · IMBIO, LLC · PI BURRIS, NICHOLAS SCOTT, HATT, CHARLES R · 2019 to 2022
$1.5M
NHLBI NIH HHS R44 HL145953
6 · The paper itself

Abstract

A serious complication in aortic dissection is dynamic obstruction of the true lumen (TL). Dynamic obstruction results in malperfusion, a blockage of blood flow to a vital organ. Clinical data reveal that increases in central blood pressure promote dynamic obstruction. However, the mechanisms by which high pressures result in TL collapse are underexplored and poorly understood. Here, we developed a computational model to investigate biomechanical and hemodynamical factors involved in Dynamic obstruction. We hypothesize that relatively small pressure gradient between TL and false lumen (FL) are sufficient to displace the flap and induce obstruction. An idealized fluid-structure interaction model of type B aortic dissection was created. Simulations were performed under mean cardiac output while inducing dynamic changes in blood pressure by altering FL outflow resistance. As FL resistance increased, central aortic pressure increased from 95.7 to 115.3 mmHg. Concurrent with blood pressure increase, flap motion was observed, resulting in TL collapse, consistent with clinical findings. The maximum pressure gradient between TL and FL over the course of the dynamic obstruction was 4.5 mmHg, consistent with our hypothesis. Furthermore, the final stage of dynamic obstruction was very sudden in nature, occurring over a short time (<1 s) in our simulation, consistent with the clinical understanding of this dramatic event. Simulations also revealed sudden drops in flow and pressure in the TL in response to the flap motion, consistent with first stages of malperfusion. To our knowledge, this study represents the first computational analysis of potential mechanisms driving dynamic obstruction in aortic dissection.

Indexed as

Aortic DissectionBlood PressureComputer SimulationHemodynamicsHumans

Identifiers

PMID36459144
PMCPMC10854260
OpenAlexW4310564188

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.