Evidence map›Paper›PMID 36456861›Full record

ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2023

Comparison of peripheral extension, acquisition time, and image chromaticity of Optos, Clarus, and EIDON systems.

Federico Fantaguzzi, Andrea Servillo, Riccardo Sacconi, Beatrice Tombolini, Francesco Bandello, Giuseppe Querques

Abstract read
PubMed Publisher
In one paragraph

Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Federico FantaguzziSchool of Medicine, Vita-Salute San Raffaele University, Via Olgettina 60, 20132, Milan, Italy.
Andrea ServilloSchool of Medicine, Vita-Salute San Raffaele University, Via Olgettina 60, 20132, Milan, Italy.
Riccardo SacconiSchool of Medicine, Vita-Salute San Raffaele University, Via Olgettina 60, 20132, Milan, Italy.
Beatrice TomboliniSchool of Medicine, Vita-Salute San Raffaele University, Via Olgettina 60, 20132, Milan, Italy.
Francesco BandelloSchool of Medicine, Vita-Salute San Raffaele University, Via Olgettina 60, 20132, Milan, Italy.
Giuseppe QuerquesSchool of Medicine, Vita-Salute San Raffaele University, Via Olgettina 60, 20132, Milan, Italy. querques.giuseppe@hsr.it.ORCID http://orcid.org/0000-0002-3292-9581

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate differences in acquisition time, peripheral extension, and chromaticity between 3 different commercialized ultra-wide-field (UWF) fundus cameras.

methodsPatients were prospectively enrolled from 07/2021 to 11/2021. Patients underwent fundus photography with the following scanning protocols: (1) single shot with Silverstone (Optos, California), two-shot montage with Clarus 500 (Carl Zeiss, Dublin, CA), and three-shot montage with iCare EIDON FA with UWF module (CenterVue Spa, a company of iCare Finland Oy; Vantaa, Finland). Acquisition time was calculated as the interval between the beginning and the end of the acquisition. Peripheral extension was quantified as the average ratio between the total retinal pixel area and the optic nerve head (ONH) pixel area. The average chromaticity of all pixels in the red-green-blue (RGB) space was calculated.

resultsTwenty-three eyes of 13 prospectively enrolled healthy controls were included in the study. Optos Silverstone had a higher total retina area/ONH area ratio (509.1 [480.9;559.3]) compared to Zeiss Clarus (442.0 [431.9;510.5], p = 0.02) and iCare EIDON (369.7 [345.3;387.8], p < 0.0001). Silverstone demonstrated the shortest acquisition time (median [interquartile range]: 32 [20;58.5] s) compared to Zeiss Clarus (42 [28.5;53.5] s, p = 0.6733) and iCare EIDON (72 [68.5;78] s, p = 0.0003). iCare EIDON demonstrated the lowest variability of acquisition time (9.5 s), compared to Zeiss Clarus (25 s) and Optos Silverstone (38.5 s). A statistically significant difference was found in the RGB distribution between each of the 3 devices (p < 0.001). iCare EIDON demonstrated an average barycenter position (RGB = [0.412, 0.314, 0.275]) that represented the best color balance of the image. Zeiss Clarus had a noticeable red shift at the expense of the blue and green channels (RGB = [0.515, 0.294, 0.191]). Optos Silverstone showed an absence of the blue channel (RGB = [0.621, 0.372, 0.007]) which results in a distortion of the color of the image.

conclusionOptos Silverstone and Zeiss Clarus required less time than iCare EIDON to acquire a comparable size image and captured larger areas of the retina than iCare EIDON. iCare EIDON provided more color-balanced retinal images with greater richness of color content than the other two devices.

Indexed as

Optic DiskRetinaDiagnostic Techniques, OphthalmologicalFluorescein AngiographyFundus OculiHumansPhotographyChromaticityFundus cameraiCare EIDONOptos SilverstoneUltra-wide-field (UWF)Zeiss Clarus

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked