Evidence map›Paper›PMID 36455526›Full record

ArticleRespiration; international review of thoracic diseases2023

Safety and Considerations of the Anaesthetic Management during Bronchoscopic Lung Volume Reduction Treatments.

Sharyn A Roodenburg, Clemens R M Barends, Grita Krenz, Eelco J Zeedijk, Dirk-Jan Slebos

Open access · hybridAbstract read
In one paragraph

Article in Respiration; international review of thoracic diseases, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Anesthesia for Bronchoscopy-An Update.Journal of clinical medicine · 2024
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Sharyn A RoodenburgDepartment of Pulmonary Diseases, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Clemens R M BarendsDepartment of Anaesthesiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Grita KrenzDepartment of Anaesthesiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Eelco J ZeedijkDepartment of Anaesthesiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
Dirk-Jan SlebosDepartment of Pulmonary Diseases, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
University Medical Center Groningen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDifferent bronchoscopic lung volume reduction approaches are available for a select group of patients with advanced COPD. General anaesthesia is the recommended method of sedation during these procedures. However, this patient population is at an increased risk of anaesthetic complications, and the best approach to general anaesthesia and mechanical ventilation is unknown.

objectivesThe aims of this study were to describe the anaesthetic management techniques used during bronchoscopic lung volume reduction procedures and to investigate the number of anaesthesia-related events.

methodsData were retrospectively collected from all endobronchial valve and lung volume reduction coil procedures performed between January 2018 and March 2020 in our hospital. Primary outcomes measures were anaesthetic technique including airway management; ventilation mode and settings; and the incidence of anaesthesia-related events, classified as catastrophic, severe, significant, or moderate.

results202 procedures were included. One procedure was performed under procedural sedation, 198 (98%) under general anaesthesia with endotracheal intubation, and 3 (1.5%) under general anaesthesia with laryngeal mask airway. Volume-controlled ventilation was used in 64% of the procedures and pressure-controlled in 36%. Patients were ventilated with a median respiration rate of 9.9 (IQR: 9.6-10.6) breaths per minute, mean tidal volume of 5.8 ± 1.4 mL/kg, and median inspiratory to expiratory (I:E) ratio of 1:2.8 (IQR: 1:2.1-1:3.2). No catastrophic anaesthesia-related events were observed. Hypotension was the most observed anaesthesia-related event.

conclusionsDespite the presence of advanced COPD, general anaesthesia and mechanical ventilation are well tolerated by patients undergoing endobronchial valve or lung volume reduction coil treatment. This is presumably strongly linked to the strict selection criteria. Other important considerations are using a low respiratory rate, low tidal volume, and high I:E ratio.

Indexed as

AnestheticsPulmonary Disease, Chronic ObstructiveHumansPneumonectomyRespiration, ArtificialRetrospective StudiesAnestheticsAnaesthesiaBronchoscopic lung volume reductionBronchoscopyChronic obstructive pulmonary diseaseMechanical ventilation

Identifiers

PMID36455526
PMCPMC9843542
OpenAlexW4310596105

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.