Evidence map›Paper›PMID 36454433›Full record

ArticleJournal of robotic surgery2023

A comparison between robot-guided and stereotactic frame-based stereoelectroencephalography (SEEG) electrode implantation for drug-resistant epilepsy.

Yuan Yao, Wenhan Hu, Chao Zhang, Xiu Wang, Zhong Zheng, Lin Sang, Xiaoqiu Shao, Kai Zhang

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 2 pooled it
2.7field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 2 syntheses or guidelines pooled it, 20 citations in OpenAlex.

  1. Pooled it
  2. Usefulness of Robotic Stereotactic Assistance (ROSANeurologia medico-chirurgica · 2024
    Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Yuan YaoDepartment of Neurosurgery, Beijing TianTan Hospital, Capital Medical University, No. 119 South 4th Ring West Road, Fengtai District, Beijing, China.
Wenhan HuBeijing Neurosurgical Institute, Capital Medical University, Beijing, China.
Chao ZhangDepartment of Neurosurgery, Beijing TianTan Hospital, Capital Medical University, No. 119 South 4th Ring West Road, Fengtai District, Beijing, China.
Xiu WangDepartment of Neurosurgery, Beijing TianTan Hospital, Capital Medical University, No. 119 South 4th Ring West Road, Fengtai District, Beijing, China.
Zhong ZhengDepartment of Neurosurgery, Beijing FengTai Hospital, Beijing, China.
Lin SangDepartment of Neurosurgery, Beijing FengTai Hospital, Beijing, China.
Xiaoqiu ShaoDepartment of Neurosurgery, Beijing TianTan Hospital, Capital Medical University, No. 119 South 4th Ring West Road, Fengtai District, Beijing, China.
Kai ZhangDepartment of Neurosurgery, Beijing TianTan Hospital, Capital Medical University, No. 119 South 4th Ring West Road, Fengtai District, Beijing, China. zhangkai62035@163.com.
Capital Medical University · CNBeijing Fengtai Hospital · CNBeijing Tian Tan Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The original stereoelectroencephalography frame-based implantation technique has been proven to be safe and effective. But this procedure is complicated and time-consuming. With the development of modern robotic technology, robot-guided intracerebral electrodes implantation is being implemented at many epilepsy centers. We retrospectively analyzed the results of 147 patients who underwent SEEG electrode implantation surgery at our hospital. Robot-guided surgery was performed on 87 patients from January 2018 to December 2019. The remaining 60 patients received frame-based surgery from June 2015 to June 2016. 147 patients underwent a total of 149 SEEG electrode implantation procedures. The mean error of the entry point of the robot-guided surgery group was lower than that of the frame-based surgery group (1.48 ± 1.46 mm vs. 1.59 ± 0.9 mm, P < 0.001). Also, the robot group had a higher mean number of electrodes per patient (8.9 ± 2.2 vs. 7.9 ± 2.5, P = 0.004), a significantly shorter mean operative time (69.5 ± 23.3 min vs. 106.8 ± 39.8 min, P < 0.001), and mean time per electrode (7.9 ± 1.3 min vs. 13.5 ± 3.1 min, P < 0.001) than the frame-based group. In the robot-guided group, the target point (TP) error was positively correlated with skull thickness (P = 0.001) and negatively correlated with the electrode-skull angle (P = 0.041). The mean target point error and hemorrhage rates were also analyzed, but no differences were observed between the two groups. Robot-guided surgery has a higher entry point accuracy and efficiency. Electrode implantation accuracy was affected by the skull thickness and electrode-skull angle.

Indexed as

Drug Resistant EpilepsyEpilepsyRoboticsRobotic Surgical ProceduresElectrodes, ImplantedElectroencephalographyHumansRetrospective StudiesDrug-resistant epilepsyFrame-basedRobot-guidedStereoelectroencephalography

Identifiers

PMID36454433
OpenAlexW4310525773

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.