Evidence map›Paper›PMID 36454430›Full record

ArticlePhysical and engineering sciences in medicine2023

Evaluation of HyperArc™ using film and portal dosimetry quality assurance.

Onno Kamst, P Desai

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Optimization of a commercial portal dose image prediction algorithm for pre-treatment verifications of plans using unflattened photon beams.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Onno KamstICON Cancer Care, Gold Coast University Hospital, Southport, Australia. okamst@gmail.com.ORCID http://orcid.org/0000-0002-4044-1754
P DesaiICON Cancer Care, Gold Coast University Hospital, Southport, Australia.
Gold Coast Health · AUGold Coast Hospital · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

HyperArc™ is a stereotactic radiotherapy modality designed for targeting multiple brain metastases using a single isocenter with multiple non-coplanar arcs. This study aimed to assess the efficacy of two patient-specific quality assurance methods, film and the Varian Portal Dosimetry System with Varian's HyperArc™ technique and raise important considerations in the customisation of patient-specific quality assurance to accommodate HyperArc™ delivery. Assessment criteria included gamma analysis and mean dose at full width half maximum. The minimum metastasis size, maximum off-axis distance and suitable energy were identified and validated. Patient-specific quality assurance procedures were applied to a range of clinically relevant brain metastasis plans. Initial investigation into energy selection showed no significant differences in gamma pass rates using 6MV, 6MV FFF, or 10MV FFF for metastasis sizes greater than 15 mm diameter at the isocenter. Gamma pass rates (2%/2mm) for 15 mm metastases at the isocenter for all energies were greater than 96.0% for portal dosimetry and greater than 98.7% for film. Fields of size 15 mm placed at various distances (10-70 mm) from the isocenter resulted in a maximum mean dose difference of 1.5% between film and planned. Clinically relevant plans resulted in a maximum mean dose difference for selected metastases of 1.0% between film and plan and a maximum point dose difference of 2.9% between portal dose and plan. Portal dose image prediction was a quick and convenient quality assurance tool for metastases larger than 15 mm near the isocenter but provided diminished geometrical relevance for off-axis metastases. Film QA required exacting procedures but offered the ability to assess the accuracy of geometrical targeting for off-axis metastases and provided dosimetric accuracy for metastases to well below 15 mm diameter.

Indexed as

Brain NeoplasmsRadiosurgeryRadiotherapy, Intensity-ModulatedHumansRadiometryRadiotherapy DosageBrain metastasesHyperArc™Portal dosimetryTrueBeam™

Identifiers

PMID36454430
OpenAlexW4310571720

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.