Evidence map›Paper›PMID 36453583›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2023

An Environmental-Inert and Highly Self-Healable Elastomer Obtained via Double-Terminal Aromatic Disulfide Design and Zwitterionic Crosslinked Network for Use as a Triboelectric Nanogenerator.

Syun-Hong Chou, Hong-Wei Lu, Ta-Chung Liu, Yi-Ting Chen, Yen-Lin Fu, Yung-Hsin Shieh, Ying-Chih Lai, San-Yuan Chen

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Ionic-Bionic Interfaces: Advancing Iontronic Strategies for Bioelectronic Sensing and Therapy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  3. Review
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Syun-Hong ChouDepartment of Materials Science and Engineering, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan.
Hong-Wei LuDepartment of Materials Science and Engineering, National Chung Hsing University, Taichung, 40227, Taiwan.
Ta-Chung LiuDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, 112304, Taiwan.
Yi-Ting ChenDepartment of Materials Science and Engineering, National Chung Hsing University, Taichung, 40227, Taiwan.
Yen-Lin FuDepartment of Materials Science and Engineering, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan.
Yung-Hsin ShiehDepartment of Materials Science and Engineering, National Tsing Hua University, Hsinchu, 300044, Taiwan.
Ying-Chih LaiDepartment of Materials Science and Engineering, National Chung Hsing University, Taichung, 40227, Taiwan.ORCID 0000-0003-4377-3313
San-Yuan ChenDepartment of Materials Science and Engineering, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan.

Funding

Ministry of Science and Technology of Taiwan 109-2112-M-005-012-MY3Ministry of Science and Technology of Taiwan 110-2221-E-005-038Ministry of Science and Technology of Taiwan 111-2314-B-A49-051-MY3Ministry of Science and Technology of Taiwan MOST 108-2221-E-009-035-MY3
6 · The paper itself

Abstract

Due to the ongoing development of portable/mobile electronics, sources to power have received widespread attention. Compared to chemical batteries as power sources, triboelectric nanogenerators (TENGs) possess lots of advantages, including the ability to harvest energy via human motions, flexible structures, environment-friendliness, and long-life characteristics. Although many self-healable TENGs are reported, the achievement of a muscle-like elasticity and the ability to recover from inevitable damage under extreme conditions (such as a high/low temperature and/or humidity) remain a challenge. Herein, a "double-terminal aromatic disulfide" on a structure with zwitterions as branched chains is reported to engineer the high-efficient self-healable elastomer for application in a flexible TENG. The as-designed material exhibits a repeatable elastic recovery (at 250% elongation) and a self-healing efficiency with an ultimate tensile stress of 96% over 2 h, representing an improvement on previously reported disulfide-based elastomers. The elastomer can autonomously recover by 50% even at a subzero temperature of -30 °C within 24 h. The elastomer-based TENG, as a self-driven sensor for detecting human behavior, is demonstrated to exhibit stable outputs and self-healing in the temperature range of -30 to 60 °C, and so is expected to promote the development of self-powered electronics for next-generation human-machine communications.

Indexed as

Cold TemperatureElastomersDisulfidesElasticityElectric Power SuppliesHumansDisulfidesElastomersautonomous self-healable materialsharsh environmenthuman-device interfacespower sourcestriboelectric nanogenerators

Identifiers

PMID36453583
PMCPMC9839881

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.