Evidence map›Paper›PMID 36452448›Full record

ArticleJournal of biomedical optics2022

High frame rate (∼3 Hz) circular photoacoustic tomography using single-element ultrasound transducer aided with deep learning.

Praveenbalaji Rajendran, Manojit Pramanik

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.5field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 19 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Praveenbalaji RajendranNanyang Technological University, School of Chemical and Biomedical Engineering, Singapore.
Manojit PramanikNanyang Technological University, School of Chemical and Biomedical Engineering, Singapore.ORCID 0000-0003-2865-5714
Nanyang Technological University · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: In circular scanning photoacoustic tomography (PAT), it takes several minutes to generate an image of acceptable quality, especially with a single-element ultrasound transducer (UST). The imaging speed can be enhanced by faster scanning (with high repetition rate light sources) and using multiple-USTs. However, artifacts arising from the sparse signal acquisition and low signal-to-noise ratio at higher scanning speeds limit the imaging speed. Thus, there is a need to improve the imaging speed of the PAT systems without hampering the quality of the PAT image. Aim: To improve the frame rate (or imaging speed) of the PAT system by using deep learning (DL). Approach: For improving the frame rate (or imaging speed) of the PAT system, we propose a novel U-Net-based DL framework to reconstruct PAT images from fast scanning data. Results: The efficiency of the network was evaluated on both single- and multiple-UST-based PAT systems. Both phantom and Conclusions: We proposed an innovative method to improve the frame rate (or imaging speed) by using DL and with this method, the fastest frame rate of

Indexed as

Deep LearningArtifactsPhantoms, ImagingTomography, X-Ray ComputedTransducerscircular photoacoustic tomographydeep learninghigh framerate imagingphotoacoustic tomography

Identifiers

PMID36452448
PMCPMC9209813
OpenAlexW4283271812

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.