In Vitro Evaluation of Nebulized Pharmaceutical Aerosol Delivery to the Lungs Using a New Heated Dryer System (HDS).

Benjamin M Spence, Worth Longest, Rabijit Dutta, Mohammad A M Momin, Sarah Strickler, Michael Hindle

Open access · greenAbstract read
In one paragraph

Article in AAPS PharmSciTech, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact, top 74% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Benjamin M SpenceDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA.ORCID http://orcid.org/0000-0002-1570-9798
Worth LongestDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA. pwlongest@vcu.edu.ORCID http://orcid.org/0000-0003-4939-5691
Rabijit DuttaDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA.
Mohammad A M MominDepartment of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia, USA.
Sarah StricklerDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia, USA.
Michael HindleDepartment of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia, USA.
Virginia Commonwealth University · US

Funding

High Efficiency Aerosol Delivery using the Excipient Enhanced Growth Concept: A Human Proof of Concept StudyR01HL107333 · NHLBI · VIRGINIA COMMONWEALTH UNIVERSITY · PI HINDLE, MICHAEL, LONGEST, P. WORTH · 2011 to 2020
$4.2M
NHLBI NIH HHS R01 HL107333
6 · The paper itself

Abstract

The objective of this study was to develop a new heated dryer system (HDS) for high efficiency lung delivery of nebulized aerosol and demonstrate performance with realistic in vitro testing for trans-nasal aerosol administration simultaneously with high-flow nasal cannula (HFNC) therapy and separately for direct oral inhalation (OI) of the aerosol. With the HDS-HFNC and HDS-OI platforms, new active synchronization control routines were developed to sense subject inhalation and coordinate drug aerosol delivery. In vitro experiments were conducted to predict regional drug loss and lung delivery efficiency in systems that included the HDS with various patient interfaces, realistic airway models, and simulated breathing waveforms. For the HDS-HFNC platform and a repeating breathing waveform, total system loss was < 10%, extrathoracic deposition was approximately 6%, and best-case lung delivery efficiency was 75-78% of nebulized dose. Inclusion of randomized breathing with the HFNC system decreased lung delivery efficiency by ~ 10% and had no impact on nasal depositional loss. For the HDS-OI platform and best-case mouthpiece, total system loss was < 8%, extrathoracic deposition was < 1%, and lung delivery efficiency was > 90% of nebulized dose. Normal vs. deep randomized oral inhalation had little impact on performance of the HDS-OI platform and environmental aerosol loss was negligible. In conclusion, both platforms demonstrated the potential for high efficiency lung delivery of the aerosol with the HDS-OI platform having the added advantages of nearly eliminating extrathoracic deposition, being insensitive to breathing waveform, and preventing environmental aerosol loss.

Indexed as

Hot TemperatureNasal SpraysAdministration, IntranasalAerosolsHumansLungAerosolsNasal Spraysdrug deliveryhigh efficiency aerosol deliveryhigh flow nasal cannulahigh flow therapypharmaceutical aerosolsrespiratory non-invasive ventilation

Identifiers

PMID36451052
PMCPMC9994751
OpenAlexW4310448139

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.