Evidence map›Paper›PMID 36447882›Full record

ArticleSurgical neurology international2022

Delayed aneurysm rupture in a patient treated with flow redirection endoluminal device: A case report and literature review.

Eisuke Tsukagoshi, Hiroki Sato, Shinya Kohyama

Open access · hybridAbstract readCase Reports
In one paragraph

Article in Surgical neurology international, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Eisuke TsukagoshiDepartment of Endovascular Neurosurgery, Saitama Medical University International Medical Center, Hidaka, Japan.
Hiroki SatoDepartment of Endovascular Neurosurgery, Saitama Medical University International Medical Center, Hidaka, Japan.
Shinya KohyamaDepartment of Endovascular Neurosurgery, Saitama Medical University International Medical Center, Hidaka, Japan.
Saitama Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Delayed aneurysm rupture after flow-redirection endoluminal device (FRED) implantation is rare. We report a case of internal carotid-cavernous fistula (CCF) caused by a delayed aneurysm rupture of the cavernous portion of the internal carotid artery (ICA) after FRED implantation. Case Description: A 75-year-old woman had a gradually enlarging aneurysm at the C4 portion of the left ICA. We performed FRED implantation for the same. The FRED implantation procedure was smooth and the FRED expanded well and attached to the vessel wall. Five days after surgery, the patient developed a strong headache, hyperemia of the left eye, and disturbance of the left eye movement. Magnetic resonance imaging and angiography revealed a left CCF with cortical venous reflux. We performed transarterial aneurysmal and transvenous cavernous sinus embolization. Postoperatively, angiography showed no fistula and complete occlusion of the aneurysm; however, minor eye movement disorder persisted. Conclusion: To prevent the development of delayed aneurysm rupture in patients treated with FRED, preoperative consideration of whether to add coil embolization is important, even if the aneurysm is located in the C4 portion of the ICA and there is no risk of subarachnoid hemorrhage, including the size of aneurysm. In this report, we have tried to alert surgeons regarding the risk of delayed aneurysm rupture due to FRED implantation.

Indexed as

Carotid cavernous fistulaDelayed aneurysmFlow-redirection endoluminal deviceInternal carotid artery

Identifiers

PMID36447882
PMCPMC9699850
OpenAlexW4308338954

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.