Evidence map›Paper›PMID 36447382›Full record

ArticleInnovations (Philadelphia, Pa.)

Novel Automated Suturing Technology for Minimally Invasive Mitral Chord Implantation: A Preclinical Evaluation Study.

Paul Werner, Claus Rath, Christoph Gross, Niv Ad, Igor Gosev, Hossein Amirjamshidi, Thomas Poschner, Iuliana Coti, Marco Russo, Markus Mach and 4 more

Open access · hybridAbstract read
In one paragraph

Article in Innovations (Philadelphia, Pa.). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Automated Annuloplasty with VirtuoSEWMedical sciences (Basel, Switzerland) · 2026
    Observational
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 4 institutions in 3 countries.

Paul WernerDepartment of Cardiac Surgery, Medical University of Vienna, Austria.ORCID 0000-0003-0925-6160
Claus RathDepartment of Cardiac Surgery, Medical University of Vienna, Austria.
Christoph GrossDepartment of Cardiac Surgery, Medical University of Vienna, Austria.
Niv AdDepartment of Surgery, University of Maryland School of Medicine, Baltimore, MD, USA.
Igor GosevDepartment of Surgery, Medical University of Rochester, NY, USA.
Hossein AmirjamshidiDepartment of Surgery, Medical University of Rochester, NY, USA.
Thomas PoschnerDepartment of Cardiac Surgery, Medical University of Vienna, Austria.
Iuliana Coti
Marco RussoSan Camillo Forlanini Hospital of Rome, Italy.
Markus MachDepartment of Cardiac Surgery, Medical University of Vienna, Austria.
Alfred KocherDepartment of Cardiac Surgery, Medical University of Vienna, Austria.
Guenther LauferDepartment of Cardiac Surgery, Medical University of Vienna, Austria.
Jude SauerDepartment of Surgery, Medical University of Rochester, NY, USA.
Martin AndreasDepartment of Cardiac Surgery, Medical University of Vienna, Austria.
Medical University of Vienna · ATUniversity of Rochester Medical Center · USCarlo Forlanini Hospital · ITUniversity of Maryland, Baltimore · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study evaluated the ergonomics and time requirements of using a novel automated suturing and titanium fastener deployment technology for chordal replacement in human heart specimens in open and minimally invasive cardiac surgery (MICS) simulators.

methodsFive cardiac surgeons used novel, manually powered expanded polytetrafluoroethylene (ePTFE) suturing devices to automate suture placement between mitral leaflets and papillary muscles in explanted cadaver hearts, along with customized titanium fastener delivery devices to secure suture and trim suture tails. This mitral chordal replacement test was conducted using surgical models simulating open and MICS mitral repair access. The study was approved by the institutional ethical board.

resultsAfter a brief introduction to this technique using plastic models, study surgeons performed 48 chordal replacements in human mitral valves, placing 18 in an open model and 30 in a right minithoracotomy model. The time range to complete a single chordal replacement was between 55 s and 8 min, with an overall mean duration of 3.6 ± 1.5 min. No difference in duration of implantation was recorded for the MICS and open sternotomy simulators used. Good control of suture delivery was reported in 95.8% (

conclusionsAutomated mitral chordal ePTFE suturing simulated through open and MICS access demonstrated quality handling and accurate placement of sutures in human heart specimens. A clinical trial using this technology is currently ongoing. This innovation may present an important advance facilitating enhanced minimally invasive mitral valve repair.

Indexed as

Heart Valve Prosthesis ImplantationMitral Valve InsufficiencyMitral Valve ProlapseChordae TendineaeHumansMitral ValvePolytetrafluoroethyleneSuturesSuture TechniquesTitaniumPolytetrafluoroethyleneTitaniumautomated ePTFE suturingchordal replacementmitral regurgitationmitral valve repairnew ePTFE titanium fastener

Identifiers

PMID36447382
PMCPMC9846373
OpenAlexW4310465394

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.