Evidence map›Paper›PMID 36445898›Full record

ArticlePloS one2022

Ultrasound insonation angle and scanning imaging modes for imaging dental implant structures: A benchtop study.

Oliver D Kripfgans, Nikhila Devi Goli, Jad Majzoub, Rafael Amorim Cavalcanti De Siqueira, Fabiana Soki, Hsun-Liang Chan

Abstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Observational
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Ultrasonography-Guided Dental Implant Surgery: A Feasibility Study.Clinical implant dentistry and related research · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Oliver D KripfgansDepartment of Radiology, Michigan Medicine, University of Michigan, Ann Arbor, MI, United States of America.
Nikhila Devi GoliDepartment of Periodontics and Oral, Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, United States of America.
Jad MajzoubDepartment of Periodontics and Oral, Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, United States of America.
Rafael Amorim Cavalcanti De SiqueiraDepartment of Periodontics, The Virginia Commonwealth University, Richmond, Virginia, United States of America.ORCID 0000-0003-4081-0959
Fabiana SokiDepartment of Periodontics and Oral, Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, United States of America.
Hsun-Liang ChanDepartment of Periodontics and Oral, Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI, United States of America.ORCID 0000-0001-5952-0447

Funding

Point of Care, High Resolution and 3-Dimensional Ultrasonography for Diagnosing Peri-Implant Bone LossR21DE027765 · NIDCR · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI CHAN, HSUN-LIANG, KRIPFGANS, OLIVER D · 2019 to 2020
$412k
NIDCR NIH HHS R21 DE027765
6 · The paper itself

Abstract

introductionHigh frequency ultrasound has shown as a promising imaging modality to evaluate peri-implant tissues. It is not known if the ultrasound imaging settings might influence ultrasound's ability to differentiate implant structures. The aim of this benchtop study was to evaluate the dependence of ultrasound on imaging angles and modes to measure implant geometry-related parameters.

methodsA clinical ultrasound scanner (ZS3, Mindray) with an intraoral probe (L30-8) offering combinations of harmonic and compound imaging modes was employed for imaging 16 abutments and 4 implants. The samples were mounted to a micro-positioning system in a water tank, which allowed a range of -30 to 30-degree imaging angles in 5-degree increment between the probe and samples. The abutment angle, implant thread pitch and depth were measured on ultrasound, compared to the reference readings. The errors were computed as a function of the image angles and modes. All samples were replicated 3 times for 3 image modes and 11 image angles, thus resulting in 2,340 images.

resultsThe mean errors of ultrasound to estimate 16 abutment angles, compared to the reference values, were between -1.8 to 2.7 degrees. The root mean squared error (RMSE) ranged from 1.5 to 4.6 degrees. Ultrasound significantly overestimated the thread pitch by 26.1 μm to 36.2 μm. The error in thread depth measurements were in a range of -50.5 μm to 39.6 μm, respectively. The RMSE of thread pitch and depth of the tested 4 implants was in a range of 34.7 to 56.9 μm and 51.0 to 101.8 μm, respectively. In most samples, these errors were independent of the image angle and modes.

conclusionsWithin the limitations of this study, high-frequency ultrasound was feasible in imaging abutments and implant fixtures independent of scanning angle within ±30° of normal incidence and for compounding and non-compounding-based imaging modes.

Indexed as

Dental ImplantsDiagnostic ImagingRadionuclide ImagingSoftwareUltrasonographyDental Implants

Identifiers

PMID36445898
PMCPMC9707752

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.