Evidence map›Paper›PMID 36443959›Full record

ArticleJournal of applied clinical medical physics2023

A method for patient-specific DVH verification using a high-sampling-rate log file in an Elekta linac.

Shiro Nishiyama, Akihiro Takemura

Full text read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. DeltaJournal of medical physics
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Shiro NishiyamaDepartment of Radiotechnology, Saiseikai Kawaguchi General Hospital, Kawaguchi, Japan.
Akihiro TakemuraFaculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We have proposed a method for patient-specific dose-volume histogram (DVH) verification using a 40-ms high-sampling-rate log file (HLF) available in an Elekta linac. Ten prostate volumetric-modulated arc therapy plans were randomly selected, and systematic leaf position errors of ±0.2, ±0.4, or ±0.8 mm were added to the 10 plans, thereby producing a total of 70 plans. An RTP file was created by interpolating each leaf position in the HLF to obtain values at each control point, which is subsequently exported to a treatment planning system. The isocenter dose calculated by the HLF-based plan to a phantom (Delta4 Phantom+) was compared to that measured by the diode in the phantom in order to evaluate the accuracy of the HLF-based dose calculation. The D95 of the planning target volume (PTV) was also compared between the HLF-based plans and the original plans with the systematic leaf position errors, the latter being referred to as theory-based plans. Sensitivities of the DVH parameters in the target, the rectum, and the bladder were also calculated with the varied systematic leaf position errors. The relative differences in the isocenter doses between the HLF-based calculations and the measurements among the 70 plans were 0.21% ± 0.67% (SD). The maximum relative differences in PTV D95 between the HLF-based and the theory-based plans among the 70 cases were 0.11%. The patient-specific DVH verification method detected a change in the target DVH parameters of less than 1% when the systematic leaf position error was ±0.2 mm. It is therefore suggested that the proposed DVH verification method may simplify patient-specific dose quality assurance procedures without compromising accuracy and sensitivity.

Indexed as

Radiotherapy, Intensity-ModulatedSoftwareHumansMalePhantoms, ImagingQuality Assurance, Health CareRadiotherapy DosageRadiotherapy Planning, Computer-Assistedlog filepatient-specific QAradiotherapyvolumetric-modulated arc therapy

Identifiers

PMID36443959
PMCPMC10018669

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read36
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.