Evidence map›Paper›PMID 36441233›Full record

ArticleAnalytical and bioanalytical chemistry2023

Investigations into the concentration and metabolite profiles of stanozolol and LGD-4033 in blood plasma and seminal fluid using liquid chromatography high-resolution mass spectrometry.

Johanna Breuer, Andreas Thomas, Philippe Delahaut, Wilhelm Schänzer, Hans Geyer, Mario Thevis

Open access · hybridAbstract read
In one paragraph

Article in Analytical and bioanalytical chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Johanna BreuerInstitute of Biochemistry, Center for Preventive Doping Research, German Sport University Cologne, Am Sportpark Müngersdorf 6, 50933, Cologne, Germany.
Andreas ThomasInstitute of Biochemistry, Center for Preventive Doping Research, German Sport University Cologne, Am Sportpark Müngersdorf 6, 50933, Cologne, Germany.
Philippe DelahautCER Groupe, Marloie, Belgium.
Wilhelm SchänzerInstitute of Biochemistry, Center for Preventive Doping Research, German Sport University Cologne, Am Sportpark Müngersdorf 6, 50933, Cologne, Germany.
Hans GeyerInstitute of Biochemistry, Center for Preventive Doping Research, German Sport University Cologne, Am Sportpark Müngersdorf 6, 50933, Cologne, Germany.
Mario ThevisInstitute of Biochemistry, Center for Preventive Doping Research, German Sport University Cologne, Am Sportpark Müngersdorf 6, 50933, Cologne, Germany. thevis@dshs-koeln.de.
German Sport University Cologne · DECentre d’Economie rurale · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Potential scenarios as to the origin of minute amounts of banned substances detected in doping control samples have been a much-discussed problem in anti-doping analysis in recent years. One such debated scenario has been the contamination of female athletes' urine with ejaculate containing doping agents and/or their metabolites. The aim of this work was to obtain complementary information on whether relevant concentration ranges of doping substances are excreted into the ejaculate and which metabolites can be detected in the seminal fluid (sf) and corresponding blood plasma (bp) samples. A method was established to study the concentration and metabolite profiles of stanozolol and LGD-4033-substances listed under anabolic substances (S1) on the World Anti-Doping Agency's Prohibited List-in bp and sf using liquid chromatography high-resolution mass spectrometry (LC-HRMS). For sf and bp, methods for detecting minute amounts of these substances were developed and tested for specificity, recovery, linearity, precision, and reliability. Subsequently, sf and bp samples from an animal administration study, where a boar orally received stanozolol at 0.33 mg/kg and LGD-4033 at 0.11 mg/kg, were measured. The developed assays proved appropriate for the detection of the target substances in both matrices with detection limits between 10 and 40 pg/mL for the unmetabolized drugs in sf and bp, allowing to estimate the concentration of stanozolol in bp (0.02-0.40 ng/mL) and in sf (0.01-0.25 ng/mL) as well as of LGD-4033 in bp (0.21-2.00 ng/mL) and in sf (0.03-0.68 ng/mL) post-administration. In addition, metabolites resulting from different metabolic pathways were identified in sf and bp, with sf resembling a composite of the metabolic profile of bp and urine.

Indexed as

Anabolic AgentsDoping in SportsAnimalsChromatography, LiquidFemaleMaleNitrilesPlasmaPyrrolidinesReproducibility of ResultsStanozololSubstance Abuse DetectionSwineTandem Mass Spectrometry4-(2-(2,2,2-trifluoro-1-hydroxyethyl)pyrrolidin-1-yl)-2-(trifluoromethyl)benzonitrileAnabolic AgentsNitrilesPyrrolidinesStanozololBlood plasmaLGD-4033Seminal fluidSports dopingStanozolol

Identifiers

PMID36441233
PMCPMC9839828
OpenAlexW4310249126

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.