Evidence map›Paper›PMID 36440272›Full record

ArticleFrontiers in neuroscience2022

To shift or to rotate? Comparison of acquisition strategies for multi-slice super-resolution magnetic resonance imaging.

Michele Nicastro, Ben Jeurissen, Quinten Beirinckx, Céline Smekens, Dirk H J Poot, Jan Sijbers, Arnold J den Dekker

Abstract read
In one paragraph

Article in Frontiers in neuroscience, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Michele Nicastroimec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium.
Ben Jeurissenimec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium.
Quinten Beirinckximec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium.
Céline Smekensimec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium.
Dirk H J PootBiomedical Imaging Group Rotterdam, Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, Netherlands.
Jan Sijbersimec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium.
Arnold J den Dekkerimec-Vision Lab, Department of Physics, University of Antwerp, Antwerp, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Multi-slice (MS) super-resolution reconstruction (SRR) methods have been proposed to improve the trade-off between resolution, signal-to-noise ratio and scan time in magnetic resonance imaging. MS-SRR consists in the estimation of an isotropic high-resolution image from a series of anisotropic MS images with a low through-plane resolution, where the anisotropic low-resolution images can be acquired according to different acquisition schemes. However, it is yet unclear how these schemes compare in terms of statistical performance criteria, especially for regularized MS-SRR. In this work, the estimation performance of two commonly adopted MS-SRR acquisition schemes based on shifted and rotated MS images respectively are evaluated in a Bayesian framework. The maximum a posteriori estimator, which introduces regularization by incorporating prior knowledge in a statistically well-defined way, is put forward as the estimator of choice and its accuracy, precision, and Bayesian mean squared error (BMSE) are used as performance criteria. Analytic calculations as well as Monte Carlo simulation experiments show that the rotated scheme outperforms the shifted scheme in terms of precision, accuracy, and BMSE. Furthermore, the superior performance of the rotated scheme is confirmed in real data experiments and in retrospective simulation experiments with and without inter-image motion. Results show that the rotated scheme allows regularized MS-SRR with a higher accuracy and precision than the shifted scheme, besides being more resilient to motion.

Indexed as

Bayesian estimationimage reconstructionmagnetic resonance imagingoptimal experimental designsuper-resolution

Identifiers

PMID36440272
PMCPMC9694825

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.