Evidence map›Paper›PMID 36439618›Full record

ArticleCureus2022

Sensitivity and Specificity of Instrumentation Lab Age-Adjusted D-Dimer Threshold Values in a Single Hospital Site: A Retrospective Analysis.

Ryan Cracknell, Ehsan Salim

Abstract read
In one paragraph

Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ryan CracknellCardiology, Golden Jubilee National Hospital, Glasgow, GBR.
Ehsan SalimRadiology, University Hospital Monklands, Glasgow, GBR.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction The D-dimer is a common test in the assessment of chest pain in acute settings. With a high sensitivity and low specificity, a significant number of false positive outcomes occur, leading to unnecessary medical intervention. There is good evidence supporting the use of an age-adjusted D-dimer model to increase diagnostic specificity in the context of a conventional "D-dimer" assay. There is, however, a lack of evidence validating the age adjustment process when considering the less common but still widely utilized "instrumentation lab" assay. Methods A retrospective audit was carried out in a district general hospital by obtaining all acute computed tomography pulmonary angiograms carried out between December 2020 and August 2021. The age-adjusted D-dimer was calculated for each patient by multiplying the patient's age by 5. Thereafter, sensitivity and specificity were reassessed. Results After exclusion, 133 patients under 50 years of age with low pre-test probability scores were included in the analysis. Age-adjusted D-dimer was found to increase specificity from 2% to 28% whilst maintaining a sensitivity of 94%. Conclusion Utilization of the 5x age-adjusted instrumentation lab assay D-dimer results in increased specificity with the potential to reduce the number of unnecessary admissions, radiation exposure, and medication use, improving patient safety and reducing healthcare burden.

Indexed as

ctpad-dimerhospital admissionpleuritic chest painpulmonary embolism

Identifiers

PMID36439618
PMCPMC9696858

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.