Evidence map›Paper›PMID 36438882›Full record

ArticleWorld journal of gastrointestinal endoscopy2022

Impact of looping on premalignant polyp detection during colonoscopy.

Osamu Toyoshima, Toshihiro Nishizawa, Shuntaro Yoshida, Tatsuya Matsuno, Toru Arano, Ryo Kondo, Kazunori Kinoshita, Yuki Yasumi, Yosuke Tsuji, Mitsuhiro Fujishiro

Open access · diamondAbstract read
In one paragraph

Article in World journal of gastrointestinal endoscopy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Osamu ToyoshimaDepartment of Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo 157-0066, Japan.
Toshihiro NishizawaDepartment of Gastroenterology and Hepatology, International University of Health and Welfare, Narita Hospital, Narita 286-8520, Japan. nisizawa@iuhw.ac.jp.
Shuntaro YoshidaDepartment of Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo 157-0066, Japan.
Tatsuya MatsunoDepartment of Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo 157-0066, Japan.
Toru AranoDepartment of Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo 157-0066, Japan.
Ryo KondoDepartment of Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo 157-0066, Japan.
Kazunori KinoshitaDepartment of Obstetrics and Gynecology, Seijo Kinoshita Hospital, Tokyo 157-0066, Japan.
Yuki YasumiDepartment of Internal Medicine, Yasumi Hospital, Morioka 028-4125, Japan.
Yosuke TsujiDepartment of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo 113-8655, Japan.
Mitsuhiro FujishiroDepartment of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo 113-8655, Japan.
The University of Tokyo · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe presence of premalignant polyps on colonoscopy is an indicator of metachronous colorectal cancer. Looping during colonoscopy is associated with old age, female sex, and colonoscopy insertion time. However, the clinical significance of looping is not fully understood. We aimed to clarify the effect of looping on colorectal premalignant polyp detection.

aimTo assess the effects of looping on premalignant polyp detection using logistic regression analyses.

methodsWe retrospectively investigated patients who underwent colonoscopy at Toyoshima Endoscopy Clinic between May, 2017 and October, 2020. From the clinic's endoscopy database, we extracted data on patient age, sex, endoscopist-assessed looping, colonoscopy duration, endoscopist experience, detection rate, and number of premalignant polyps.

resultsWe assessed 12259 patients (mean age, 53.6 years; men, 50.7%). Looping occurred in 54.3% of the patients. Mild and severe looping were noted in 4399 and 2253 patients, respectively. The detection rates of adenomas, advanced adenomas, high-risk adenomas, clinically significant serrated polyps (CSSPs), and sessile serrated lesions (SSLs) were 44.7%, 2.0%, 9.9%, 8.9% and 3.5%, respectively. The mean numbers of adenomas and SSLs were 0.82 and 0.04, respectively. The detection rates of adenomas, high-risk adenomas, and CSSPs increased with looping severity (all

conclusionLooping severity was independently associated with high detection rates of premalignant polyps. Therefore, looping may predict the risk of metachronous colorectal cancer. Endoscopists should carefully examine the colorectum of patients with looping.

Indexed as

AdenomaColonoscopyColorectal neoplasmColorectal polypLoopingSerrated polyp

Identifiers

PMID36438882
PMCPMC9693685
OpenAlexW4309044475

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.