ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2026
A novel 3-Fr guiding sheath for transradial access in aneurysm embolization: Technical note.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Bilateral transradial access using a 3-Fr guiding sheath for coil embolization of basilar artery aneurysms associated with challenging vertebral artery anatomy: An initial experience and future prospects.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Preliminary Experience With Novel Straight 3-Fr Guiding Sheath for Transradial Access in Endovascular Treatment: Feasibility and Safety.Operative neurosurgery (Hagerstown, Md.) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Neurointervention via transradial access (TRA) is challenging when the radial artery is narrow. We performed aneurysm embolization via TRA using a novel 3-Fr guiding sheath (GS) (Axcelguide; Medikit, Tokyo, Japan) with an outer diameter of only 1.76 mm for patients with a radial artery of inner diameter less than 2 mm, and described the whole procedure and pitfalls as a technical note. Here, we present two patients with radial arteries less than 2 mm. One patient had a narrow neck intracranial aneurysm at the bifurcation of the left vertebral artery and posterior inferior cerebellar artery, which was embolized with the primary coiling technique. The other was a patient with a wide-necked extracranial aneurysm in the cavernous portion of the right internal carotid artery, which was embolized with the transcell technique with stent. We utilized a 3-Fr GS, distal access catheter, and a 0.0165-inch microcatheter for coil embolization. All aneurysms were completely occluded, without neurological or puncture site-related complications including subcutaneous hematoma, radial artery occlusion, and vasospasm. This report provides the first description of neurointervention using a 3-Fr GS. The 3-Fr GS contributed to successful completion of TRA aneurysm embolization without neurological or puncture site-related complications in patients with radial arteries narrower than 2 mm. The 3-Fr GS may be useful to accomplish aneurysmal embolization via TRA even in patients with a small radial artery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.