Evidence map›Paper›PMID 36437048›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2023

Multiplexed Complementary Signal Transmission for a Self-Regulating Artificial Nervous System.

Young Jin Choi, Dong Gue Roe, Yoon Young Choi, Seongchan Kim, Sae Byeok Jo, Hwa Sung Lee, Do Hwan Kim, Jeong Ho Cho

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Multiplexed Complementary Signal Transmission for a Self-Regulating Artificial Nervous System.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Young Jin ChoiDepartment of Chemical and Biomolecular Engineering, Yonsei University, Seoul, 03722, Republic of Korea.
Dong Gue RoeSchool of Electrical and Electronic Engineering, Yonsei University, Seoul, 03722, Republic of Korea.
Yoon Young ChoiDepartment of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
Seongchan KimSKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon, 16419, Republic of Korea.
Sae Byeok JoSchool of Chemical Engineering, SKKU Institute of Energy Science and Technology (SIEST), Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea.
Hwa Sung LeeDepartment of Materials Science and Chemical Engineering, Hanyang University, Ansan, 15588, Republic of Korea.
Do Hwan KimDepartment of Chemical Engineering, Hanyang University, Seoul, 04763, Republic of Korea.
Jeong Ho ChoDepartment of Chemical and Biomolecular Engineering, Yonsei University, Seoul, 03722, Republic of Korea.ORCID 0000-0002-1030-9920

Funding

Creative Materials Discovery Program through the National Research Foundation of Korea (NRF) funded by Ministry of Science and ICT NRF-2019M3D1A1078299National R&D Program through the NRF funded by Ministry of Science and ICT 2021M3D1A2049315
6 · The paper itself

Abstract

Neuromorphic engineering has emerged as a promising research field that can enable efficient and sophisticated signal transmission by mimicking the biological nervous system. This paper presents an artificial nervous system capable of facile self-regulation via multiplexed complementary signals. Based on the tunable nature of the Schottky barrier of a complementary signal integration circuit, a pair of complementary signals is successfully integrated to realize efficient signal transmission. As a proof of concept, a feedback-based blood glucose level control system is constructed by incorporating a glucose/insulin sensor, a complementary signal integration circuit, an artificial synapse, and an artificial neuron circuit. Certain amounts of glucose and insulin in the initial state are detected by each sensor and reflected as positive and negative amplitudes of the multiplexed presynaptic pulses, respectively. Subsequently, the pulses are converted to postsynaptic current, which triggered the injection of glucose or insulin in a way that confined the glucose level to a desirable range. The proposed artificial nervous system demonstrates the notable potential of practical advances in complementary control engineering.

Indexed as

NeuronsSynapsesGlucoseInsulinGlucoseInsulinartificial nervous systemhealthcaremulti-level regulationSchottky barrier transistorsignal multiplexing

Identifiers

PMID36437048
PMCPMC9875628

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.