ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2023
Patient-specific 3D printing to replace components of a rib-to pelvis "Eiffel Tower" vertebral expanding prosthetic titanium rib system in an infant: a case report.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo address the anatomical challenges facing complex and revision spinal surgery, patient-specific 3D-printed models (3D-PMs) have received growing attention worldwide, primarily in adults. We report the use of a 3D-PM in the treatment of a case of wound breakdown over a component of a VEPTR (Vertical Expandable Prosthetic Titanium Rib; DePuy-Synthes) system, requiring replacement of Dunn-McCarthy hook and sleeve with components contoured to a patient-specific 3D-PM of the spine.
methodA two-year-old born with myelomeningocele (MMC), repaired at birth, developed progressive MMC-associated kyphoscoliosis. Elective insertion of a rib-to-pelvis 'Eiffel Tower' bilateral VEPTR growing rods construct was performed without initial complication. Prominence of the right VEPTR sleeve and Dunn-McCarthy hook side-to-side connector resulted in breakdown of overlying poor-quality soft tissues, necessitating washout, partial implant removal, intravenous antibiotic therapy and delayed primary wound closure. A patient-specific 3D-PM, utilising pre-operative CT spine and pelvis 3D-reconstructions, allowed pre-operative formation of a contoured implant, which was inserted without need for further revision.
resultsThe patient underwent further VEPTR lengthening without recurrent infection, wound breakdown or implant failure at 24-month follow-up. Satisfactory control of the deformity has been achieved with continued improvement in sitting height and radiographic indices.
conclusionThis case illustrates the possibility, in certain cases, of using 3D-PM to develop complex components of spinal implant systems pre-operatively, removing the time and difficulty of intra-operative contouring. Consequently, custom-contoured implants may be produced, sterilised and implanted. This technique may be an option, in infants, including MMC-associated kyphoscoliosis, where midline fixation is not possible.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.