Evidence map›Paper›PMID 36434261›Full record

ArticleJournal of robotic surgery2023

Preliminary outcomes of kinematically aligned robot-assisted total knee arthroplasty with patient-specific cartilage thickness measurement.

Kayhan Turan, Yalkin Camurcu, Murat Kezer, Yunus Uysal, Yusuf Onur Kizilay, Abdulaziz Temiz

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Review
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kayhan TuranDepartment of Orthopaedics and Traumatology, Turan & Turan Health Group, Ulubatlı Hasan Bulvari 48/62, Osmangazi, 16220, Bursa, Turkey.ORCID http://orcid.org/0000-0002-1164-6857
Yalkin CamurcuDepartment of Orthopaedics and Traumatology, Turan & Turan Health Group, Ulubatlı Hasan Bulvari 48/62, Osmangazi, 16220, Bursa, Turkey. yalkin.camurcu@gmail.com.ORCID http://orcid.org/0000-0002-3900-5162
Murat KezerDepartment of Orthopaedics and Traumatology, Turan & Turan Health Group, Ulubatlı Hasan Bulvari 48/62, Osmangazi, 16220, Bursa, Turkey.ORCID http://orcid.org/0000-0001-6684-1636
Yunus UysalDepartment of Orthopaedics and Traumatology, Turan & Turan Health Group, Ulubatlı Hasan Bulvari 48/62, Osmangazi, 16220, Bursa, Turkey.ORCID http://orcid.org/0000-0002-0094-8622
Yusuf Onur KizilayDepartment of Orthopaedics and Traumatology, Turan & Turan Health Group, Ulubatlı Hasan Bulvari 48/62, Osmangazi, 16220, Bursa, Turkey.ORCID http://orcid.org/0000-0001-8373-3426
Abdulaziz TemizDepartment of Orthopaedics and Traumatology, Turan & Turan Health Group, Ulubatlı Hasan Bulvari 48/62, Osmangazi, 16220, Bursa, Turkey.ORCID http://orcid.org/0000-0002-6467-0025

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to assess the preliminary outcomes of kinematically aligned robot-assisted total knee arthroplasty (TKA) with patient-specific cartilage thickness measurement. Patients who underwent kinematically aligned robot-assisted TKA were included in this study. Robot-assisted total knee arthroplasties were performed by NAVIO Surgical System (Smith & Nephew, Memphis, USA), an image-free handheld robotic system. The kinematic alignment technique was performed according to our intraoperative cartilage thickness measurement technique. Hip-knee-ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), joint-line orientation angle (JLOA), and joint-line convergence angle (JLCA) were measured through standing full-length anteroposterior radiographs. Knee Injury and Osteoarthritis Outcome Score, Oxford score, VAS pain and satisfaction score, and Forgotten Joint Score were used to assess clinical outcomes. A total of 142 knees of 109 patients (92 females and 17 males) were evaluated in this study. There was a significant correction in HKA, JLCA, and mMPTA postoperatively (p ≤0.001, < 0.001, and 0.029, respectively). We observed no significant change in mLDFA and JLOA measurements. All clinical scores significantly increased at the latest follow-up. Our results demonstrated that kinematically aligned robot-assisted TKA with patient-specific cartilage thickness measurement demonstrated no significant change in mLDFA and JLOA, as expected; however, significantly corrected the deformity in HKA, mMPTA, and JLCA measurements.

Indexed as

Arthroplasty, Replacement, KneeRoboticsRobotic Surgical ProceduresBiomechanical PhenomenaFemaleHumansKnee JointMaleRetrospective StudiesTibiaCartilage thicknessKinematic alignmentRobot-assistedTotal knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.