ArticleSensors (Basel, Switzerland)2022
Output Characterization of 220 nm Broadband 1250 nm Wavelength-Swept Laser for Dynamic Optical Fiber Sensors.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Broadband wavelength-swept lasers (WSLs) are widely used as light sources in biophotonics and optical fiber sensors. Herein, we present a polygonal mirror scanning wavelength filter (PMSWF)-based broadband WSL using two semiconductor optical amplifiers (SOAs) with different center wavelengths as the gain medium. The 10-dB bandwidth of the wavelength scanning range with 3.6 kHz scanning frequency was approximately 223 nm, from 1129 nm to 1352 nm. When the scanning frequency of the WSL was increased, the intensity and bandwidth decreased. The main reason for this is that the laser oscillation time becomes insufficient as the scanning frequency increases. We analyzed the intensity and bandwidth decrease according to the increase in the scanning frequency in the WSL through the concept of saturation limit frequency. In addition, optical alignment is important for realizing broadband WSLs. The optimal condition can be determined by analyzing the beam alignment according to the position of the diffraction grating and the lenses in the PMSWF. This broadband WSL is specially expected to be used as a light source in broadband distributed dynamic FBG fiber-optic sensors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.