ArticleSensors (Basel, Switzerland)2022
MEMSbased Double-Stacked Tower Biosensor Array with Integrated Readout Circuitry for Detection of Salivary pH as a Diagnostic Biomarker Applied for Chronic Periodontal Disease.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
Abstract
MEMS based 3D double stacked tower pixel biosensor 10 × 10 array with integration of readout circuit for detection of saliva pH ion is demonstrated. The pixel biosensor comprised a driving electrode, sensing electrode and double stack tower pixel structure. The sensitivity of double stacked tower biosensor can be auxiliary enhanced by proposed lower-jitter low dropout regulator circuit and dual offset cancellation comparator. The double stacked tower sensor is fabricated by MEMS backend-of-line CMOS process, it is compatible with CMOS frontend readout circuits and integrated as a system-on-chip (SoC). The double stacked tower pixel by MEMS process is to obtain a larger volume ratio of charge groups in a pixel of biosensor to enhance the sensitivity and linearity for ion detection. With the double stacked tower structure in biosensor, the sensitivity is improved by 31% than that of single tower structure proved by simulation. A wide-range linearity from pH 2.0 to pH 8.3, high sensitivity of -21 ADC counts/pH (or 212 mV/pH), response time of 5 s, repetition of 98.9%, and drift over time of 0.5 mV are achieved. Furthermore, the proposed biosensor was performed to confirm the artificial saliva from healthy gingiva, chronic gingivitis and chronic periodontitis, the measured ADC counts from proposed biosensor SoC was in consistent of that measured cyclic voltametric (CV) method very well. The proposed 3D double stack tower biosensor and readout circuit can be further integrated with internet-of-thing (IoT) device and NFC for data transmission for continuous pH sensing to facilitate the chronic gingiva disease health care at home.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.