Evidence map›Paper›PMID 36433203›Full record

ArticleSensors (Basel, Switzerland)2022

Machine-Learning Classification of Pulse Waveform Quality.

Te Ouyoung, Wan-Ling Weng, Ting-Yu Hu, Chia-Chien Lee, Li-Wei Wu, Hsin Hsiu

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Te OuyoungDivision of Family Medicine, Department of Family and Community Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan.
Wan-Ling WengGraduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.
Ting-Yu HuGraduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.
Chia-Chien LeeGraduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.
Li-Wei WuDivision of Family Medicine, Department of Family and Community Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan.ORCID 0000-0003-4744-7646
Hsin HsiuGraduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.ORCID 0000-0001-6761-3774
National Taiwan University of Science and Technology · TWTri-Service General Hospital · TW

Funding

Ministry of Science and Technology Taiwan MOST 111-2221-E-011 -017 -MY2National Taiwan University of Science and Technology-Tri-Service General Hospital Joint Research Program TSGH-NTUST-110-05; TSGH-NTUST-111-07; TSGH-A-110005, MND-MAB-110-129
6 · The paper itself

Abstract

Pulse measurements made using wearable devices can aid the monitoring of human physiological condition. Accurate estimation of waveforms is often difficult for nonexperts; motion artifacts may occur during tonometry measurements when the skin-sensor contact pressure is insufficient. An alternative approach is to extract only high-quality pulses for use in index calculations. The present study aimed to determine the effectiveness of using machine-learning analysis in discriminating between high-quality and low-quality pulse waveforms induced by applying different contact pressures. Radial blood pressure waveform (BPW) signals were measured noninvasively in healthy young subjects using a strain-gauge transducer. One-minute-long trains of pulse data were measured when applying the appropriate contact pressure (67.80 ± 1.55 mmHg) and a higher contact pressure (151.80 ± 3.19 mmHg). Eight machine-learning algorithms were employed to evaluate the following 40 harmonic pulse indices: amplitude proportions and their coefficients of variation and phase angles and their standard deviations. Significant differences were noted in BPW indices between applying appropriate and higher skin-surface contact pressures. The present appropriate contact pressure could not only provide a suitable holding force for the wearable device but also helped to maintain the physiological stability of the underlying tissues. Machine-learning analysis provides an effective method for distinguishing between the high-quality and low-quality pulses with excellent discrimination performance (leave-one-subject-out test: random-forest AUC = 0.96). This approach will aid the development of an automatic screening method for waveform quality and thereby improve the noninvasive acquisition reliability. Other possible interfering factors in practical applications can also be systematically studied using a similar procedure.

Indexed as

Machine LearningRadial ArteryBlood PressureHeart RateHumansReproducibility of Resultscontacting pressuremachine learningpulsespectral analysiswaveform quality

Identifiers

PMID36433203
PMCPMC9698948
OpenAlexW4308507707

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.