Evidence map›Paper›PMID 36431196›Full record

ReviewJournal of clinical medicine2022

Effect of Continuous Renal Replacement Therapy with the oXiris Hemofilter on Critically Ill Patients: A Narrative Review.

Yupei Li, Peiyan Sun, Kaixi Chang, Mei Yang, Ningyue Deng, Shanshan Chen, Baihai Su

Open access · goldAbstract readReview
In one paragraph

Review in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed, 1 pooled it
5.2field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 1 synthesis or guideline pooled it, 38 citations in OpenAlex.

  1. Guideline
  2. Review
  3. Review
  4. Observational
  5. Review
  6. Article
  7. Article
  8. Observational
  9. Association of oXirisJournal of personalized medicine · 2025
    Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Yupei LiDepartment of Nephrology, West China Hospital, Sichuan University, Chengdu 610041, China.ORCID 0000-0002-7364-3731
Peiyan SunWest China School of Medicine, Sichuan University, Chengdu 610041, China.
Kaixi ChangDepartment of Nephrology, West China Hospital, Sichuan University, Chengdu 610041, China.
Mei YangDepartment of Nephrology, West China Hospital, Sichuan University, Chengdu 610041, China.
Ningyue DengDepartment of Nephrology, West China Hospital, Sichuan University, Chengdu 610041, China.
Shanshan ChenDepartment of Nephrology, West China Hospital, Sichuan University, Chengdu 610041, China.
Baihai SuDepartment of Nephrology, West China Hospital, Sichuan University, Chengdu 610041, China.ORCID 0000-0002-2187-8168
Sichuan University · CN

Funding

1.3.5 Project for Disciplines of Excellence from West China Hospital of Sichuan University ZYJC21010Med+ Biomaterial Institute of West China Hospital/West China School of Medicine of Sichuan University ZYME20001Med-X Innovation Programme of Med-X Center for Materials of Sichuan University MCM202101Sichuan Science and Technology Program 2022YFS0147
6 · The paper itself

Abstract

Critically ill patients with sepsis and severe COVID-19 are commonly characterized by a dysregulated immune response and an acute kidney injury. Continuous renal replacement therapy (CRRT) is now proposed as a promising adjuvant therapy to treat these critically ill patients by removing cytokines, pathogen-associated molecular patterns, and damage-associated molecular patterns from the blood. Although multiple hemofilters, including high-cutoff membranes, the oXiris hemofilter, the CytoSorb hemoadsorption device, and the Toraymyxin hemoperfusion cartridge, have been used in current clinical practice, the use of the oXiris hemofilter in critically ill patients is of particular interest because it is the only kind of hemofilter that can provide renal replacement therapy, remove endotoxins, and adsorb cytokines simultaneously. During the past five years, a growing body of literature has shown that CRRT with the oXiris hemofilter can improve hemodynamics and organ function and can decrease cytokines and endotoxins in both septic and COVID-19 patients. Here, we performed a narrative review to describe the development history of the oXiris hemofilter and to discuss the therapeutic effect of oXiris-CRRT on critically ill patients by searching the PubMed, Web of Science, and clinicaltrials.gov databases for articles published from inception to 8 September 2022 (updated on 1 November) with an English language restriction. We also summarized the current knowledge on anticoagulation techniques and safety concerns when delivering oXiris-CRRT sessions.

Indexed as

acute kidney injurycontinuous renal replacement therapycritical illnessimmune dysfunctionoXiris hemofilter

Identifiers

PMID36431196
PMCPMC9695587
OpenAlexW4309424040

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.