Evidence map›Paper›PMID 36428955›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Correlation between CT Value on Lung Subtraction CT and Radioactive Count on Perfusion Lung Single Photon Emission CT in Chronic Thromboembolic Pulmonary Hypertension.

Toshiya Kariyasu, Haruhiko Machida, Tsuneo Yamashiro, Keita Fukushima, Masamichi Koyanagi, Kenichi Yokoyama, Makiko Nishikawa, Toru Satoh

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Toshiya KariyasuDepartment of Radiology, Faculty of Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan.
Haruhiko MachidaDepartment of Radiology, Faculty of Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan.
Tsuneo YamashiroDiagnostic Radiology, Yokohama City University, 3-9, Fukuura, Kanazawa-ku, Yokohama-shi 236-0004, Kanagawa, Japan.ORCID 0000-0002-1904-2548
Keita FukushimaDepartment of Radiology, Kyorin University Hospital, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan.
Masamichi KoyanagiDepartment of Radiology, Kyorin University Hospital, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan.
Kenichi YokoyamaDepartment of Radiology, Faculty of Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan.
Makiko NishikawaDepartment of Radiology, Tokyo Women's Medical University Adachi Medical Center, 4-33-1 Kohoku, Adachi-ku 123-8558, Tokyo, Japan.
Toru SatohDepartment of Cardiology, Faculty of Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan.
Kyorin University · JPKyorin University Hospital · JPTokyo Women's Medical University Adachi Medical Center · JPYokohama City University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Lung subtraction CT (LSCT), the subtraction of noncontrast CT from CT pulmonary angiography (CTPA) without spatial misregistration, is easily applicable by utilizing a software-based deformable image registration technique without additional hardware and permits the evaluation of lung perfusion as iodine accumulation, similar to that observed in perfusion lung single photon emission CT (PL-SPECT). The aim of this study was to use LSCT to newly assess the quantitative correlation between the CT value on LSCT and radioactive count on PL-SPECT as a reference and validate the quantification of lung perfusion by measuring the CT value in chronic thromboembolic pulmonary hypertension (CTEPH). Methods: We prospectively enrolled 47 consecutive patients with CTEPH undergoing both LSCT and PL-SPECT; we used noncontrast CT, CTPA, and LSCT to measure CT values and PL-SPECT to measure radioactive counts in areas representing three different perfusion classes—no perfusion defect, subsegmental perfusion defect, and segmental perfusion defect; we compared CT values on noncontrast CT, CTPA, and LSCT and radioactive counts on PL-SPECT among the three classes, then assessed the correlation between them. Results: Both the CT values and radioactive counts differed significantly among the three classes (p < 0.01 for all) and showed weak correlation (ρ = 0.38) by noncontrast CT, moderate correlation (ρ = 0.61) by CTPA, and strong correlation (ρ = 0.76) by LSCT. Conclusions: The CT value measurement on LSCT is a novel quantitative approach to assess lung perfusion in CTEPH and only correlates strongly with radioactive count measurement on PL-SPECT.

Indexed as

chronic thromboembolic pulmonary hypertensionCT pulmonary angiographylung subtraction CTquantitative assessment

Identifiers

PMID36428955
PMCPMC9688979
OpenAlexW4309686774

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.