Evidence map›Paper›PMID 36428848›Full record

ArticleDiagnostics (Basel, Switzerland)2022

The Outcome- or Cost-Effectiveness Analysis of LUS-Based Care or CXR-Based Care of Neonatal Lung Diseases: The Clinical Practice Evidence from a Level Ⅲ NICU in China.

Jing Liu, Xin Zhang, Yan Wang, Jie Li, Wei Yan, Sheng-Juan Qin, Xiao-Ling Ren, Wei Fu

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.

  1. Guideline
  2. [The necessity of routine use of critical care ultrasound in neonatal intensive care units].Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics · 2026
    Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 1 country.

Jing LiuDepartment of Neonatology and NICU, Beijing Chao-Yang Hospital, Capital Medical University, Beijing 100043, China.ORCID 0000-0002-1735-840X
Xin ZhangDepartment of Neonatology and NICU, Zhumadian Central Hospital of Henan Province, Zhumadian 463003, China.
Yan WangDepartment of Neonatology and NICU, The Affiliated Taian City Central Hospital of Qingdao University, Taian 271000, China.
Jie LiDepartment of Neonatology and NICU, Zaozhuang Maternal and Child Healthcare Hospital of Shandong Province, Zaozhuang 277100, China.
Wei YanDepartment of Ultrasound, Zhumadian Central Hospital of Henan Province, Zhumadian 463003, China.
Sheng-Juan QinDepartment of Neonatology and NICU, Beijing Chao-Yang District Maternal and Child Healthcare Hospital, Beijing 100021, China.
Xiao-Ling RenDepartment of Neonatology and NICU, Beijing Chao-Yang Hospital, Capital Medical University, Beijing 100043, China.
Wei FuDepartment of Neonatology and NICU, Beijing Chao-Yang District Maternal and Child Healthcare Hospital, Beijing 100021, China.
Beijing Chao-Yang Hospital, Capital Medical University · CNCapital Medical University · CNZhumadian Central Hospital · CNQingdao University · CNZaozhuang Municipal Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the effect of managing neonatal lung disease with lung ultrasound (LUS) or chest X-ray (CXR) monitoring on health outcomes and cost-effectiveness.

methodsThe data obtained from the NICU of the Beijing Chaoyang District Maternal and Child Healthcare Hospital were used as the study group, as LUS has completely replaced CXR in managing newborn lung disease in the hospital for the past 5 years. The primary outcomes of this study were the misdiagnosis rate of respiratory distress syndrome (RDS), the using status of mechanical ventilation, the incidence rate of bronchopulmonary dysplasia (BPD) and the survival rate in hospitalized infants. The secondary outcomes included the use pulmonary surfactant (PS), and the mortality rate of severe diseases (such as pneumothorax, pulmonary hemorrhage and RDS, etc.).

resultsManaging neonatal lung disease with LUS monitoring may enable the following effects: The frequency of ventilator use reducing by 40.2%; the duration of mechanical ventilation reducing by 67.5%; and the frequency of ventilator weaning failure being totally avoided. A misdiagnosis rate of 30% for RDS was also avoided. The dosage of PS was significantly reduced by 50% to 75%. No BPD occurred in the LUS-based care group for 5 years. The fatality rates of RDS, pneumothorax and pulmonary hemorrhage decreased by 100%. The poor prognosis rate of VLBW infants decreased by 85%, and the total mortality rate of hospitalized infants decreased by 90%. Therefore, the cost of LUS-based care was inevitably saved.

conclusionsDiagnosing and managing neonatal lung diseases with LUS monitoring have significant benefits, and this technology should be widely promoted and applied around the world.

Indexed as

chest X-ray (CXR)health authoritieslung diseaselung ultrasound (LUS)newborn infantsoutcome-effectiveness or cost-effectiveness