ArticleFrontiers in surgery2022
Alignment analysis of Brainlab knee 3 navigation-guided total knee arthroplasty using the adjusted mechanical method.
Article in Frontiers in surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 12 citations in OpenAlex.
- A comparative study of clinical and radiographic outcomes in total knee arthroplasty assisted by the CT-free Smith & Nephew CORI robotic system versus the Brainlab Knee3 navigation system.Journal of robotic surgery · 2026Article
- Comparative analysis of perceptions on artificial intelligence in surgery: a survey study among surgeons and medical students in Ireland.Irish journal of medical science · 2025Article
- Application and postoperative rehabilitation effects of HURWA, Cori, and Brainlab robots in TKA under the ERAS concept.Journal of robotic surgery · 2025Article
- Standardizing definitions of the total knee alignment techniques: recommendations by the Personalized Arthroplasty Society.EFORT open reviews · 2025Review
- Short learning curve associated with robotic total knee arthroplasty: A retrospective study.Journal of experimental orthopaedics · 2025Article
- Long-term outcomes of computer-assisted Ci™ navigation versus conventional total knee arthroplasty.Joint diseases and related surgery · 2025Article
- A Retrospective Study to Compare Patient Outcomes from Standard Total Knee Arthroplasty (TKA) versus Navigation-Guided Arthroplasty Using the Brainlab Software-Guided Surgical System at a Center in Hebei Province January 2021 to July 2023.Medical science monitor : international medical journal of experimental and clinical research · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: With the application of navigation technology in Total Knee Arthroplasty (TKA), TKA procedures have become various. Studies have shown that navigation can improve the alignment of patients' lower limbs. To verify this conclusion, we collected the clinical data from patients who underwent Brainlab knee 3 navigation-guided TKA. Brainlab knee 3 is a completely new software that takes a different approach to address the current challenges of navigated TKA. During the procedure, we applied the Adjusted Mechanical Alignment (AMA) principle and took soft tissue balance as a priority. We aim to explore the patients' lower limb alignment changes who underwent the Brainlab knee 3 navigation-guided TKA using the AMA method. Methods: Fifty consecutive patients who underwent total knee arthroplasty using the Brainlab knee3 knee navigation system (Smith&Nephew) from January to August 2021 by the same doctor (Yunsu Chen) in the Department of Joint Surgery of the Shanghai Sixth People's Hospital were included. Hip-Knee-Ankle Angle (HKAA), anatomic Femur Tibia Angle (FTA), Lateral Distal Femoral Angle (LDFA), and medial proximal tibia angle (MPTA) were measured on preoperative and postoperative full-length lower-limbs x-ray films or weight-bearing anterior and lateral knee radiographs for observational and descriptive study. The preoperative and postoperative knee alignment changes were analyzed through paired Results: Pre-operative and post-operative HKAA both obeyed normal distribution. The mean preoperative HKAA was 169.8° (154.9-178.7°) with a standard deviation of 5.41; the postoperative HKAA was 175.7° (168.4-180.0°) with a standard deviation of 2.81. Using the two-sample paired Conclusion: In our study, AMA alignment was applied in Brainlab Knee3 computer navigation-assisted total knee arthroplasty. The femoral and tibial osteotomy angles were minimally adjusted according to soft tissue situations to reduce soft tissue release. We found AMA alignment provides good control of knee alignment in the coronal plane of the lower limbs, which is a reliable technique.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.