ArticleJournal of hand surgery global online2022
The Effect of Locking Screws on Distal Component Fixation in Total Wrist Arthroplasty Using a Cadaver Model.
Article in Journal of hand surgery global online, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Muscle Forces and Articular Loading Following In Vitro Total Wrist Arthroplasty.Journal of wrist surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The advent of total wrist arthroplasty has allowed for motion-sparing surgical treatment for wrist arthritis. The Integra Freedom Total Wrist Arthroplasty recently incorporated locking caps into its distal component fixation to minimize implant micromotion and improve osseous integration. The purpose of this study was to assess the kinematic effect of locking caps in a cadaveric model. Methods: The Integra Freedom was implanted in 4 matched-pair cadavers and tested with and without the use of the locking caps, with the testing order randomized. Each specimen was tested on a custom testing system in a position of 15° of radial deviation, neutral position, and 15° of ulnar deviation with 25 N, 50 N, 75 N, and 100 N of compressive force. The rotation of the capitate, trapezoid, and hamate at all positions was measured using a 3-dimensional digitizer. Results: Statistical analysis showed no difference in carpal rotation between the nonlocking cap and locking cap groups at all testing loads and wrist positions. The absolute motion of the distal row was minimal. However, of the total 216 loads/positions tested, only 4 (1.8%) showed a rotation of greater than 2° and only 34 (15.7%) showed a rotation of greater than 1°. Conclusions: This study shows that in a time zero cadaveric model, the initial osseous fixation of the distal component in the Integra Freedom is robust with or without locking caps. The addition of locking caps did not have a kinematic effect on distal carpal row fixation. However, further investigation into its clinical role is necessary. Clinical Relevance: At time zero, there is minimal carpal motion after implantation of the Integra Freedom Total Wrist with functional loading. The addition of locking caps did not lead to any decrease in carpal motion.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.