Evidence map›Paper›PMID 36424980›Full record

ArticlePhysics and imaging in radiation oncology2022

Multicenter comparison of measures for quantitative evaluation of contouring in radiotherapy.

Mark J Gooding, Djamal Boukerroui, Eliana Vasquez Osorio, René Monshouwer, Ellen Brunenberg

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Review
  2. Quantifying manual editing time in autocontouring via audit log analysis.Physics and imaging in radiation oncology · 2026
    Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Review
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mark J GoodingMirada Medical Ltd, Oxford, United Kingdom.
Djamal BoukerrouiMirada Medical Ltd, Oxford, United Kingdom.
Eliana Vasquez OsorioUniversity of Manchester, Manchester, United Kingdom.
René MonshouwerRadboud University Medical Centre, Nijmegen, the Netherlands.
Ellen BrunenbergRadboud University Medical Centre, Nijmegen, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Purpose: A wide range of quantitative measures are available to facilitate clinical implementation of auto-contouring software, on-going Quality Assurance (QA) and interobserver contouring variation studies. This study aimed to assess the variation in output when applying different implementations of the measures to the same data in order to investigate how consistently such measures are defined and implemented in radiation oncology. Materials and Methods: A survey was conducted to assess if there were any differences in definitions of contouring measures or their implementations that would lead to variation in reported results between institutions. This took two forms: a set of computed tomography (CT) image data with "Test" and "Reference" contours was distributed for participants to process using their preferred tools and report results, and a questionnaire regarding the definition of measures and their implementation was completed by the participants. Results: Thirteen participants completed the survey and submitted results, with one commercial and twelve in-house solutions represented. Excluding outliers, variations of up to 50% in Dice Similarity Coefficient (DSC), 50% in 3D Hausdorff Distance (HD), and 200% in Average Distance (AD) were observed between the participant submitted results. Collaborative investigation with participants revealed a large number of bugs in implementation, confounding the understanding of intentional implementation choices. Conclusion: Care must be taken when comparing quantitative results between different studies. There is a need for a dataset with clearly defined measures and ground truth for validation of such tools prior to their use.

Indexed as

ContouringDice Similarity CoefficientHausdorff DistanceQuality AssuranceRadiotherapySimilarity measure

Identifiers

PMID36424980
PMCPMC9679364

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.